Skip to main content
Schneider Electric EVS32H4MW5A

Schneider Electric EVS32H4MW5A EasyPact EVS Circuit Breaker,

MPN EVS32H4MW5A
Active

Schneider Electric EasyPact EVS series, EVS32H4MW5A, manually operated circuit breaker, 4 poles, 3200 A rated current, 65 kA Icu at 440 V AC, drawout mounting, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS32H4MW5A key specifications
ParameterValue
Control typeManually operated
Display typeDigital display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS32H4MW5A additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
ApplicationDistribution
Operating temperature-5...70 °C

Product details

What this 3200 A drawout breaker brings to a distribution board

The Schneider Electric EVS32H4MW5A is a 4-pole EasyPact EVS circuit breaker rated for 3200 A continuous at 40 °C, with a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. The drawout mounting (rails and base plate included) lets you rack the breaker out for maintenance or replacement without disturbing the bus connections, which is the standard practice for switchgear where downtime on a 3200 A feeder is measured in minutes, not hours. The EVS Trip System5A electronic trip unit handles overload (long-time), short-time, and instantaneous short-circuit protection, with a 20-minute thermal memory that remembers the heat profile before and after a trip — so if you reclose on a hot breaker, it won't let a second overload cook the cable. The digital display shows fault type (overload, short-circuit, internal fault) and measured current, which saves the panel guy from guessing what tripped it.

At 3200 A and 65 kA Icu, this breaker sits in the heavy end of the EasyPact EVS range — it's sized for main incomers or large bus risers, not branch feeders. The Category B utilization (IEC 60947-2) means it's designed for selectivity with downstream breakers: the short-time delay lets a fault ride through long enough for the nearest downstream device to clear, keeping the rest of the board live. Electrical durability is 5000 cycles at rated voltage without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. That's enough for a main breaker that cycles once or twice a day, not a switching-duty device. The IP40 enclosure keeps tools and fingers out but isn't washdown-rated; it's for clean indoor switchgear.

Integration notes — drawout frame, connections, and isolation

Mounts on a rail or base plate with rear vertical or horizontal connections spaced at 115 mm pitch without a spreader. The drawout design means you need racking clearance above and below — 395 mm depth and 441 mm width give the panel builder the envelope to plan gland plates and bus bar takeoffs.

MPN
EVS32H4MW5A