Skip to main content
Schneider Electric GV4L25N6

Schneider Electric GV4L25N6 TeSys GV4 Motor Circuit Breaker,

MPN GV4L25N6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4L25N6, 3-pole, 25 A rated current, magnetic-electronic trip, 100 kA breaking capacity at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4L25N6 key specifications
ParameterValue
Control typeRotary handle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

GV4L25N6 additional specifications
ParameterValue
Storage temperature-50...85 °C
Pollution degree3
ColorGrey (RAL 7016)
Depth165 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 20000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The GV4L25N6 is a 3-pole motor circuit breaker from the TeSys GV4 range, rated at 25 A continuous current (In) and designed for motor protection under AC-3 utilisation category per IEC 60947-4-1. The 25 A rating means it directly protects a motor drawing up to that full-load current — for a 400 V supply that translates to roughly 5.5 kW, while at 690 V it covers up to 7.5 kW. The magnetic-electronic trip unit provides adjustable magnetic tripping between 150 and 350 A, so you set the instantaneous pickup to ride through motor inrush without nuisance trips. The part is rated for isolation (IEC 60947-1), so it doubles as a disconnect under load.

Connection pitch is 27 mm without spreaders and 35 mm with them, which matters when laying out busbars or cable ducts in a crowded enclosure. Terminals accept lugs or ring terminals for cable sizes from 1.5 to 95 mm², with tightening torques of 5 N·m for smaller cables and 9 N·m for the larger ones. The IP40 front face and IK07 impact rating mean it is suited for general industrial panel environments where occasional tool drops or dust ingress are concerns. Pollution degree 3 confirms it for conductive environments typical of factory floors.

Climatic withstand conforms to IACS for marine environments. Fire resistance is tested to 960 °C per IEC 60695-2-11. Storage temperature range is -50 to 85 °C.

MPN
GV4L25N6