Schneider Electric LC1F1854Q7

Schneider Electric LC1F1854Q7 TeSys F Contactor, 275 A AC-1,

MPN LC1F1854Q7
Obsolete

Schneider Electric TeSys F, LC1F1854Q7, 4-pole contactor, 275 A AC-1 rated operational current, 380 V AC 40-400 Hz coil, plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F1854Q7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage690 V AC 50/60 Hz
Coil voltage380 V AC 40...400 Hz
Current275 A (at <40 °C) at <= 440 V AC-1
Breaking capacity1480 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-60...80 °C

All specifications

LC1F1854Q7 additional specifications
ParameterValue
Depth181 mm
Width208.5 mm
Height174 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load
Operating time35 ms closing at Uc) 130 ms opening at Uc)
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The LC1F1854Q7 is flagged end-of-life (EOL) by the manufacturer.

The headline rating is 275 A at ≤ 440 V in AC-1 utilisation category (resistive load). AC-1 is the continuous-current rating for heater banks, lighting, or transformer primary switching — not motor starting. For motor duty (AC-3), the power dissipation per pole drops to 12 W versus 25 W in AC-1, so the contactor's thermal capacity is sized for the resistive curve. The 4 NO power poles are all normally open; there are no built-in auxiliary contacts on this base unit. The control circuit is a 380 V AC coil rated for 40–400 Hz, with an inrush of 1070 VA and a hold-in consumption of 9.9 VA. The coil pickup range is 0.85–1.1 Uc at 55 °C; dropout occurs between 0.2 and 0.55 Uc. This means a 380 V nominal coil will hold in down to roughly 323 V and drop out between 76 V and 209 V — relevant for brownout coordination in a control panel. The contactor is plate-mounted (not DIN-rail), so panel layout must account for the 181 mm depth, 208.5 mm width, and 174 mm height. Power-circuit connections accept bar (25 x 3 mm busbar), lugs (150 mm² cable), or bolted connections — typical for a panel builder wiring a high-current resistive load bank. The part is certified to IEC 60947-4-1 and EN 60947-4-1 (the contactor standard), plus IEC 60947-1 and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand of 8 kV. The front face carries IP2X protection with shrouds — finger-safe but not washdown-rated.

Deployment Context

This contactor is sized for a 275 A resistive load in a panel — typically a large oven, furnace, or transformer bank. The plate-mount form factor and bar/lug power connections mean it integrates into a busbar system, not a DIN-rail assembly. The 380 V AC coil ties directly into a 380 V control transformer; no DC supply or rectifier is needed.