Skip to main content
Schneider Electric LUCB05FUTQ

Schneider Electric LUCB05FUTQ TeSys U Advanced Control Unit

MPN LUCB05FUTQ
Obsolete

Schneider Electric TeSys U advanced control unit LUCB05FUTQ, 1.5 kW at 400...440 V AC, manual reset, plug-in front face, 45 x 66 x 60 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LUCB05FUTQ specifications
ParameterValue
Main product or component typeAdvanced control unit
Voltage690 V AC
Coil voltage110...220 V DC 110...240 V AC
Utilization categoryAC-41 AC-43 AC-44
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Depth60 mm
Width45 mm
Height66 mm
ApplicationMotor control Motor protection
Fixing modePlug-in (front face)
Operating temperature-25...70 °C

Product details

The LUCB05FUTQ is an advanced control unit from the TeSys U range, designed for basic protection and advanced functions including communication. It handles 3-phase motor loads — self-cooled — and delivers motor power ratings of 1.5 kW at 400...440 V AC 50/60 Hz, 2.2 kW at 500 V AC 50/60 Hz, and 3 kW at 690 V AC 50/60 Hz. That means it covers the common European 400 V line and steps up to 690 V for higher-voltage installations. The unit provides protection against overload, short-circuit, phase failure, phase imbalance, and earth faults. It resets manually, which is standard for a motor-protective device — you want a deliberate action after a trip, not an automatic restart that could catch maintenance off-guard. It mounts via a plug-in front face onto a TeSys U base, so the control unit swaps without disturbing the power wiring.

The control circuit voltage is 110...240 V AC and 110...220 V DC — a wide-range supply that covers most industrial control voltages without needing a separate transformer tap. Utilisation categories AC-41, AC-43, and AC-44 mean the unit is rated for switching resistive, motor, and other inductive loads under the IEC 60947-6-2 standard for motor starters and controllers. Rated insulation voltage is 690 V per IEC 60947-6-2 and 600 V per UL 60947-4-1 and CSA C22.2 No 60947-4-1, with a phase barrier required for the UL/CSA listing. That matters if the panel must carry a UL 508A label — the phase barrier is a mandatory add-on, not optional.

Where the TeSys U control unit is used

The LUCB05FUTQ lives inside a motor control centre or a standalone starter enclosure, plugged into a TeSys U power base that carries the contactor and overload sensing. It is the brains of the starter — it monitors current, decides when to trip, and communicates status. Above that, the air density drops and the thermal performance changes — standard for any electromechanical device, but worth noting if the panel is headed to a high-altitude site.

MPN
LUCB05FUTQ