Skip to main content
Schneider Electric LUCB18FUTQ

Schneider Electric LUCB18FUTQ TeSys U Advanced Control Unit,

MPN LUCB18FUTQ
Obsolete

Schneider Electric TeSys U advanced control unit, LUCB18FUTQ, manual reset, 7.5 kW at 400 V AC, plug-in front face, IP20 front panel.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LUCB18FUTQ specifications
ParameterValue
Load type3-phase motor - cooling: self-cooled
Main product or component typeAdvanced control unit
Voltage690 V AC
Coil voltage110...220 V DC 110...240 V AC
Insulation voltage ui690 V conforming to IEC 60947-6-2 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
Utilization categoryAC-43 AC-44 AC-41
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Depth60 mm
Width45 mm
Height66 mm
ApplicationMotor control Motor protection
Fixing modePlug-in (front face)
Operating time35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 50 ms closing with LUB32 for control circuit 50 ms closing with LUB38 for control circuit
Operating temperature-25...70 °C

Product details

TeSys U advanced control unit for motor protection and control

It provides manual reset, protection against overload, short-circuit, phase failure, phase imbalance, and earth fault. The unit is rated for motor power up to 7.5 kW at 400...440 V AC, 9 kW at 500 V AC, and 15 kW at 690 V AC, all at 50/60 Hz. It operates with a control circuit voltage of 110...240 V AC or 110...220 V DC.

The 7.5 kW rating at 400 V AC tells you this unit directly matches a standard 7.5 kW IEC motor on a 400 V three-phase supply — no external overload relay needed. The utilisation categories AC-41, AC-43, and AC-44 cover resistive loads, squirrel-cage motors with starting currents up to 6× Ir, and more severe duty cycles like frequent starting or plugging. The tripping threshold of 14.2 × Ir ± 20 % sets the magnetic short-circuit release point, so it clears a bolted fault fast without nuisance tripping on normal motor inrush.

The LUCB18FUTQ mounts via plug-in (front face) into a TeSys U power base or starter. IP20 on the front panel and wired terminals keeps it safe for enclosed panel use; IP40 on the front panel outside the connection zone adds a bit more splash protection. The TH protective treatment per IEC 60068 means it's coated for humid or mildly corrosive environments.

The unit carries approvals to EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1 (with phase barrier), and CSA C22.2 No 60947-4-1 (with phase barrier). Safe separation of circuits is maintained at 400 V SELV between control/auxiliary and main circuits. It withstands 2 kV common mode and 1 kV serial mode non-dissipating shock waves, 4 kV fast transients on all circuits except serial link, and radiated fields up to 10 V/m.

MPN
LUCB18FUTQ