Skip to main content
Schneider Electric VW3AP3420

VW3AP3420 Altivar Encoder Interface, EnDat/SSI, 1000 kHz

MPN VW3AP3420
Active

Schneider Altivar VW3AP3420, digital encoder interface module, EnDat 2.2 / SSI / A/B/I incremental, 1× female high-density SUB-D 15, 5–24 VDC supply, 1000 kHz max frequency.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

VW3AP3420 specifications
ParameterValue
Connector type1 female high density SUB-D 15
Main product or component typeDigital encoder interface module
Maximum cable distance between devices100 m (A/B/I) 50 m (SSI) 100 m (SSI)at 300 kHz 50 m (EnDat 2.2) 100 m (EnDat 2.2)with propagation delay compensation
Input impedance121 Ohm

Product details

What it handles — encoder types and signal lines

The VW3AP3420 is a digital encoder interface module in the Altivar drive family, designed to connect incremental (A/B/I) and absolute (SSI, EnDat 2.2) encoders to the drive control board. It accepts EnDat 2.2 bidirectional data (Data+/Data-, Clock+/Clock-), SSI clock/data lines, and standard quadrature A+/A-, B+/B-, I+/I- plus temperature sensor inputs (Temp+/Temp-). One female high-density SUB-D 15 connector carries all signals. Maximum operating frequency is 1000 kHz, so it handles high-resolution encoder feedback for precision speed or position loops on servo and closed-loop induction motors.

Supply voltage and current draw

The module is powered from the encoder supply, not the drive backplane — three voltage ranges are supported: 5 VDC (4.75–5.25 V limits), 12 VDC (11.4–12.6 V), and 24 VDC (22.8–25.2 V). Maximum current draw is 0.25 A at 5 V, 0.1 A at 12 V, and 0.05 A at 24 V. The 121 Ω input impedance is fixed for the differential line receivers. Overload and short-circuit protection are built into the interface, so a faulted encoder cable won't take out the drive's encoder supply channel.

Cable distance limits by protocol

Maximum cable length between the encoder and the module depends on the protocol and speed: 100 m for A/B/I incremental, 100 m for EnDat 2.2 with propagation delay compensation enabled, 100 m for SSI at 300 kHz, or 50 m for SSI at full speed and 50 m for EnDat 2.2 without compensation. The 1000 kHz limit applies to the A/B/I incremental channel.

Sourcing note — not a standalone part

Lifecycle status is active per Schneider's current listing — the module is still in regular production. One important procurement constraint: the VW3AP3420 cannot be ordered alone; it is only available in combination with a standard Altivar enclosure (i.e. as part of a drive order or as a field-installed option kit bundled with the drive).

MPN