ABB 1SDA068158R1

ABB 1SDA068158R1 XT4N 160 Ekip LSIG, 40 A, 4-Pole MCCB

MPN 1SDA068158R1

ABB XT4N 160 molded-case circuit breaker, Ekip LSIG trip unit, In 40 A, Iu 160 A, 4-pole, 690 V, 50/60 Hz, fixed front terminals.

$1,101.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

1SDA068158R1 specifications
ParameterValue
Product typeXT4N 160 Ekip LSIG In=40 A 4p F F
Voltage690 V
Current40 A
Frequency50/60 Hz
Poles4 poles
Weight3.1 Kg
DimensionsXT4

Product details

Frame rating vs trip setting — why both numbers matter

The 1SDA068158R1 is an ABB XT4N 160 breaker with a 40 A Ekip LSIG trip unit plugged into a 160 A frame. The Iu (160 A) is the maximum continuous current the breaker body and terminals can carry; the In (40 A) is the installed protection setting. This means the same breaker shell can be re-trip'd up to 160 A by swapping the electronic trip unit — useful if the load grows and you want to avoid pulling the whole breaker. The Ekip LSIG trip provides L (long-time), S (short-time), I (instantaneous), and G (ground-fault) protection curves. The G function is the differentiator here — it detects leakage currents down to the trip unit's adjustable threshold, which matters for personnel protection on IT or TN-S systems where a standard LI or LSI breaker would miss a ground fault until it became a phase fault.

4-pole switching — when you need to break the neutral

Four poles means all three phases plus the neutral are switched and protected. This is mandatory in TN-S or TT distribution where the neutral is a current-carrying conductor that must be isolated for safe maintenance. It also simplifies coordination in dual-source transfer schemes where the neutral path must be broken to prevent circulating currents. Rated 690 V, so it covers 400 V and 480 V systems with headroom for voltage swells, and it's suitable for 690 V industrial grids common in mining, marine, and heavy process plants. The 50/60 Hz rating means it's at home on either side of the pond.

Sourcing and lifecycle — still a catalog item

Estimated lead time is 2-4 weeks, which is typical for a built-to-order MCCB. Not a stocked shelf item, but the lead time is standard for the class and predictable for project planning.