Skip to main content
Schneider Electric A9C62310

Schneider Electric A9C62310 Reflex iC60N, 10A 3P C-curve MCB

MPN A9C62310
Active

Schneider Electric Acti9 Reflex iC60N integrated control circuit breaker, 10 A, 3P, curve C, 20 kA breaking capacity.

$419.06 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C62310 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width99 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationDistribution Control

Product details

It combines overcurrent protection with remote switching in a single 3-pole unit, rated at 10 A with a C trip curve. The thermal-magnetic trip handles distribution and control panel loads, while the integrated control coil allows remote ON/OFF via maintained or impulse signals at 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC.

Breaking capacity and fault clearing

Breaking capacity is 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC, both per EN/IEC 60947-2. That means it clears high fault currents on a 230 V distribution bus without upstream coordination headaches. The N breaking capacity code places it in the standard-duty tier for commercial and light industrial panels.

Dimensions are 99 mm wide by 84 mm high by 77 mm deep, occupying 11 DIN pitches. That's a standard 3-pole MCB footprint — no surprises for a panel layout.

Control and signaling

The control circuit accepts multiple voltage options — 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC — with maintained or impulse commands. Local signaling uses a multi-color LED: green for ON, flashing for device ready or tripped, red for fault. A contact position indicator and padlock provision in the OFF position add safety for lockout/tagout.

Durability and environmental specs

Rated for 50,000 electrical cycles under AC-1 resistive load and 50,000 mechanical cycles. Tropicalisation class 2 and 93% relative humidity at 40 °C mean it handles coastal or unconditioned plant environments.

MPN