Skip to main content
Schneider Electric A9N18542

Schneider Electric A9N18542 Acti9 Vigi C120 4P 125A 30mA RCD

MPN A9N18542
Obsolete

Schneider Electric Acti9 Vigi C120, add-on residual current device, A9N18542, 4P, 125A, 30 mA AC type, instantaneous, 400-415 V AC.

$276.63 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18542 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400...415 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width198 mm
Height95 mm
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9N18542 is an add-on residual current device (RCD) from the Acti9 Vigi C120 range, designed to clip onto the outgoing side of a compatible Acti9 MCB or switch-disconnector. It provides earth-leakage protection for a 4-pole circuit rated at 125 A, with a 30 mA sensitivity and instantaneous trip characteristic.

Rated at 125 A continuous and 400-415 V AC, this unit handles the full load current of a large submain or a heavy commercial outgoing group. The instantaneous trip means no intentional delay; it clears a fault within tens of milliseconds, which is appropriate for final circuits but not for selectivity against downstream RCDs. The residual current trip mechanism is voltage-independent — it does not rely on the mains voltage to operate. That means it still trips even if the neutral is lost upstream, a genuine safety advantage over electronic RCDs in TN or TT systems where a broken neutral can otherwise leave the circuit unprotected.

The unit is 198 mm wide, which is 10 modules of 9 mm pitch. It connects to the upstream MCB or switch via screws and accepts tunnel terminals up to 50 mm² rigid or 35 mm² flexible. Factor the 198 mm width into your DIN-rail layout — it occupies ten 9 mm slots, so plan the enclosure fill accordingly.

MPN