ATV6A0C11Q6 specifications
ParameterValue
Main product or component typeVariable speed drive
Current118.0 A 690 V normal duty) 100.0 A 690 V heavy duty)
Frequency50...60 Hz - 5...5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.1 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2
Data format8 bits, configurable odd, even or no parity Modbus serial
Operating temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor

Product details

ATV6A0C11Q6 is a cabinet-mount Altivar Process ATV600 drive delivering 110 kW at 690 V normal duty (90 kW heavy duty). Line current draws 118 A at 690 V normal duty, 100 A heavy duty — those figures govern supply cable sizing and branch protection. The integrated EMC filter meets IEC 61800-3 category C3, which covers most industrial distribution without external add-ons. Safety function STO SIL3 is built in, no external safety relay required for machine stop circuits. Communication flexibility: slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP, or CANopen module; slot A/B can take digital/analog I/O or relay extension. That gives network integration options without changing the base drive SKU.

Cabinet mount only (UL type 1 or 12 with cabinet integration). Forced convection cooling — ensure clearance for airflow. Line side connection via screw terminals or M10 bar; motor connection via M10 bars. Control wiring: removable screw terminals, 0.5…1.5 mm². Switching frequency adjustable 2…4.9 kHz with derating factor — higher frequencies reduce motor noise but increase dissipation. The drive's protection suite includes thermal, overcurrent, short-circuit, overvoltage, undervoltage, phase loss, and overspeed. One power module and control unit kit with mechanical mounting parts and fuse set included.