Skip to main content
Schneider Electric ENW13210

Schneider Electric ENW13210 EasyPact NW Circuit Breaker, 800

MPN ENW13210
Active

Schneider Electric EasyPact NW, ENW13210, 3-pole fixed circuit breaker, 800 A rated current, 66 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW13210 key specifications
ParameterValue
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP30
Terminal pitch70 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-40...85 °C

All specifications

ENW13210 additional specifications
ParameterValue
Pollution degreeclass 3
Depth196 mm
Width276 mm
Height301 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

The ENW13210 is a 3-pole EasyPact NW circuit breaker from Schneider Electric, rated 800 A at 40 °C and carrying a 66 kA Icu at 220...440 V AC 50/60 Hz per IEC 60947-2. Category B utilization means it's designed for distribution duty with selective coordination, not just cable protection. Rated insulation voltage (Ui) is 1000 V AC, and impulse withstand (Uimp) is 12 kV, so it's comfortable on 400/480 V systems with decent margin for switching surges. Short-time withstand (Icw) is 50 kA for 1 second — that's the current it can carry without damage during a delayed trip coordination sequence, which is the spec you need when setting up a selective tripping scheme with downstream breakers. That's the standard for unsealed switchgear in factory environments — no special derating needed for typical panel conditions.

Fixed mount on a rail base plate, rear-connected. Dimensions are 276 mm wide × 301 mm high × 196 mm deep. Connection pitch is 70 mm without spreader, which is the standard for this frame size — busbar drilling patterns and cable lug spacing should match that centerline.

MPN