Skip to main content
Schneider Electric A9C63410

A9C63410 Reflex iC60N Ti24 10 A 4P curve D integrated contro

MPN A9C63410
Obsolete

Schneider Electric Acti9 Reflex iC60N Ti24, integrated control circuit breaker, 10 A, 4P, curve D, 20 kA at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C63410 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width117 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationDistribution Control

Product details

The Schneider Electric A9C63410 is an Acti9 Reflex iC60N Ti24 integrated control circuit breaker — a 4-pole, 10 A thermal-magnetic MCB with a D curve that also packs remote switching, local signalling, and padlocking into a single DIN-rail module. It's not just a breaker; it's a control element that replaces a separate contactor + MCB pair in distribution and control panels.

Breaking capacity and selectivity — what the ratings actually mean

This Reflex iC60N carries a 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC, per EN/IEC 60947-2. At 240 V, 20 kA puts it in the 'high fault' tier for a 10 A breaker; you can coordinate it downstream of a 25 kA or 36 kA upstream device without worrying about cascading failure. The 'N' breaking capacity code means it's the standard (not 'H' high or 'L' limited) variant in the iC60 family.

Integration — what it connects to and how it mounts

At 117 mm wide (13 x 9 mm pitch modules), it occupies the same footprint as a 4P MCB plus a separate contactor would, but in one unit. Control voltage options cover 24 V DC, 48 V DC, 24 V AC, 48 V AC, and 230 V AC — pick the one your PLC or pushbutton station already runs. The remote control accepts pulse ON/OFF, continuous command, or toggle signals, so it works with a simple maintained switch or a momentary pushbutton. Earth-leakage protection is handled by a separate Vigi block downstream — this unit doesn't include RCD functionality.

What the local signalling tells you

The Reflex iC60N has a multi-colour LED on the front: green for ON, flashing green for ready, flashing for tripped, red for fault, and flashing for overheat. That's enough to walk a field tech through a fault without opening the panel door — green = normal, flashing = thermal trip or overload, red = short-circuit or internal fault. The padlock provision (OFF position only) lets you lock it out for maintenance without removing the breaker.

MPN
A9C63410