Skip to main content
Schneider Electric A9F44470

Schneider Electric A9F44470 iC60N MCB, 0.5 A, C Curve, 4P

MPN A9F44470
Obsolete

Schneider Electric Acti9 iC60N miniature circuit breaker, A9F44470, 0.5 A rated current, C curve, 4 poles, 50 kA breaking capacity at 415 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F44470 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F44470 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F44470 is an Acti9 iC60N miniature circuit breaker rated at 0.5 A with a C curve, 4 poles, and a 50 kA breaking capacity at 415 V AC. This dual certification gives you flexibility in panel design — the part can serve in a distribution board or an industrial control panel without requalifying the BOM line.

For a C curve, the magnetic trip threshold is 8 x In +/- 20 %.

The 72 mm width occupies 8 x 9 mm pitches, so it fills a standard 4-module slot in a distribution board. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible, with a 2 Nm tightening torque. Strip length is 14 mm. IP20 finger-safe terminals — suitable for enclosed panels, not for washdown environments.

MPN