Schneider Electric C104TM050C

Schneider Electric C104TM050C ComPacT NSX TM-D Trip Unit, 50

MPN C104TM050C
Active

Schneider Electric ComPacT NSX, TM-D trip unit, thermal-magnetic, 50 A at 50 °C, 4 poles 4D, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C104TM050C specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeTrip unit
Voltage690 V AC 50/60 Hz 750 V DC
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C104TM050C is a TM-D thermal-magnetic trip unit for the ComPacT NSX100...250 range, rated 50 A at 50 °C, 4 poles 4D. It provides LI protection — thermal overload (L) and magnetic short-circuit (I) — per EN/IEC 60947-2. The 50 A rating at 50 °C means this trip unit is sized for a 50 A continuous load in a 50 °C ambient; if your panel runs hotter, you'll need to derate or step up to the next rating.

Mounts fixed into ComPacT NSX100...250 circuit breaker frames. The trip unit is a plug-in module — no wiring to the breaker itself, just snap it into the cradle. Neutral position is left, which matches standard panel layout for 4-pole breakers where the neutral lug is on the left side. IP40 front face keeps out tools and fingers; the breaker body itself handles the enclosure seal.

The long-time pickup (Ir) is adjustable from 0.7 to 1 x In, so you can dial the 50 A trip unit down to 35 A if the load is lighter — that's one SKU covering a range of feeder sizes. The instantaneous pickup (Ii) is fixed at 500 A (10 x In), which gives a good balance between nuisance trip avoidance and short-circuit protection for distribution feeders. Thermal delay (tr) is fixed at 120-400 s at 1.5 x In and 15 s at 6 x Ir — no field adjustment on the time curve, so coordination studies need to account for the fixed band. Rated operational voltage is 690 V AC 50/60 Hz and 750 V DC, covering most industrial distribution voltages up to 600 V class.

MPN
C104TM050C