Skip to main content
Schneider Electric ENW13277

ENW13277 EasyPact NW Switch Disconnector, 1600A, 3P

MPN ENW13277
Active

Schneider Electric EasyPact NW switch disconnector, ENW13277, 1600 A, 3 poles, fixed mounting, AC-23A, 440 V, IEC 60947-3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW13277 key specifications
ParameterValue
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz conforming to IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-3
CurrentAC-23 A: 1600 A AC 50/60 Hz 440 V
Utilization categoryAC-23 A
IP ratingIP30
Terminal pitch70 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-40...85 °C

All specifications

ENW13277 additional specifications
ParameterValue
Pollution degreeclass 3
Depth196 mm
Width276 mm
Height301 mm
Mechanical life cycles20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3
ApplicationDistribution
Operating temperature-5...70 °C

Product details

Switch disconnector, 1600 A, 3 poles — fixed-mount isolation for distribution

The ENW13277 is a fixed-mount switch disconnector from the EasyPact NW range, rated 1600 A in AC-23A duty at 440 V AC — meaning it handles motor and mixed loads with frequent switching, not just resistive circuits. The 3-pole design suits three-phase distribution panels where you need visible-break isolation (IEC 60947-3 certified). Mounts on a rail base plate with rear connection; the 70 mm connection pitch without spreader keeps busbar layout clean.

The headline number is 1600 A in AC-23A — that's the current it can make and break for motor loads (high inrush, up to 10× running). For distribution-only duty (AC-21A or AC-22A) it would carry more, but AC-23A is the tougher call. The short-time withstand (Icw) is 50 kA for 1 second at 220-440 V; the making capacity (Icm) is 75 kA. That tells you it can sit upstream of a fault and hold closed long enough for a downstream breaker to clear — selectivity headroom. Electrical durability: 5000 cycles at 440 V in AC-23A without maintenance. Mechanical durability: 20,000 cycles with maintenance, 10,000 without. That's not a daily-switch duty cycle; it's a load-break isolator for infrequent operation.

MPN