Schneider Electric LX0FF224

TeSys LX0FF224 Contactor Coil, 220 V Latching / 24 V Unlatch

MPN LX0FF224
Obsolete

TeSys F contactor coil, LX0FF224, 220 V AC/DC latching / 24 V AC/DC unlatching, 35-40 ms latching operating time.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX0FF224 specifications
ParameterValue
Control circuit typeAC at 50...400 Hz DC standard
Main product or component typeContactor coil
Coil voltage220 V AC 50...400 Hz latching 24 V AC 50...400 Hz unlatching 220 V DC latching 24 V DC unlatching
Mechanical life cycles1 Mcycles
Operating time35...40 ms latching 50...100 ms unlatching

Product details

The LX0FF224 is a TeSys F contactor coil — the replaceable solenoid that pulls in and holds the main power contacts on a TeSys F frame contactor. It is a dual-voltage design: the latching circuit operates at 220 V AC/DC while the unlatching (hold-in) circuit runs at 24 V AC/DC, which means the coil draws high inrush to close the contacts then drops to a lower hold-in voltage, reducing continuous power dissipation in the panel. Operating time is 35 to 40 ms for latching (closing) and 50 to 100 ms for unlatching (opening), so the contactor responds fast enough for motor starting and general switching duty but not for high-speed semiconductor switching.

Control circuit and integration notes

The control circuit accepts AC at 50 to 400 Hz or DC, standard for industrial panels where a 220 V control transformer feeds the latching circuit and a separate 24 V supply handles the hold-in. The coil resistance measures 29.5 Ω for the latching winding and 39.5 Ω for the unlatching winding at 20 °C — useful for calculating inrush current and verifying the control transformer sizing. Voltage tolerance is 0.85 to 1.1 times the rated control voltage on both circuits, so a 220 V latching supply can sag to 187 V and still pull the contactor in. Mounts directly onto the TeSys F contactor base; no additional wiring adapter needed. The coil terminals accept standard ring or fork crimp terminals. Panel builders should verify the control transformer VA rating covers the latching inrush — the 29.5 Ω resistance at 220 V implies roughly 7.5 A peak inrush, though the hold-in current at 24 V is under 1 A.

MPN
LX0FF224