Overview
The 140CPU67861: It carries a fiber optic LC single-mode link for primary-secondary PLC synchronization up to 16 km, plus one Modbus Plus, one Modbus, and one USB port for local and network connectivity.
Schneider 140CPU67861 Plc Expansion Modules — now discontinued, supplied from remaining surplus and broker stock.
| Parameter | Value |
|---|---|
| Range of product | Modicon Quantum automation platform |
| Product or component type | Unity processor |
| Integrated connection type | 1 Modbus Plus 1 Modbus 1 USB 1 optic fibre Hot Standby |
| Bus current requirement | 2760 mA |
| Clock frequency | 266 MHz |
| Communication service | Ethernet router |
| Electrical connection | 1 female connector SUB-D 9 for connecting to the Modbus Plus network 1 connector RJ45 for connecting Modbus bus 1 connector LC (single mode fiber optic) for interconnecting primary and secondary PLCs up to 16 km |
| Maximum number of connections | 1 USB 2 AS-Interface - distributed 4 AS-Interface - remote 6 Ethernet TCP/IP - local 6 Modbus Plus - local 6 Profibus DP - local 1 Modbus RS232/485 Modbus/ASCII) |
| Standards | HazLoc |
| Checks | Hot standby Process control |
| Category | 18150-QUANTUM CONTROLLERS,HSBY,COMM. |
| Number of racks | 2 - local |
| Parameter | Value |
|---|---|
| Number of slots | 10 16 4 6 2 |
| Switch function | Key switch memory port on/off |
| System overhead | 0.2 ms fast task 1 ms master task |
| Local signalling | 1 LED (green) for Ethernet activity (COM) 1 LED (red) for Ethernet collision |
| Memory description | Expandable 8 MB - file storage with PCMCIA card Internal RAM 11264 kB - 1536 kB for data |
| Analogue i (O number) | 500 inputs, 500 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 1984 inputs,1984 outputs - remote 0 - local - forbidden in Hot Standby application |
| Discrete i (O number) | 31744 inputs, 31744 outputs - remote 8000 inputs, 8000 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 0 - local - forbidden in Hot Standby application |
| Mode of transmission | Single mode |
| Protective treatment | Conformal coating Humiseal 1A33 |
| Application structure | 1 periodic fast task - forbidden in Hot Standby application 128 I/O interrupt tasks - forbidden in Hot Standby application 128 interrupt tasks - forbidden in Hot Standby application 32 timer interrupt tasks - forbidden in Hot Standby application 4 auxiliary tasks - forbidden in Hot Standby application 1 cyclic/periodic master task - |
| Application specific i (O) | Serial link High-speed interrupt inputs Accurate time stamping Counter |
| Number of optional modules | 6 Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max) |
| Number of remote i (O station) | 31 - 2 S908 remote I/O 31 - 2 ethernet Quantum remote I/O 31 - 2 ethernet X80 remote I/O |
| Number of instructions per | 10.28 Kinst/ms 100 % Boolean 10.07 Kinst/ms 65 % Boolean and 35 % numerical |
| Number of distributed i (O station) | 63 1 3 Modbus Plus |
The 140CPU67861: It carries a fiber optic LC single-mode link for primary-secondary PLC synchronization up to 16 km, plus one Modbus Plus, one Modbus, and one USB port for local and network connectivity.