Specifications
| Parameter | Value |
|---|---|
| Product type | Basic frame |
| Product name | MasterPact NT |
| Range | MasterPact |
| Circuit breaker name | MasterPact NT16H2 |
| Control unit | Without control unit |
| Parameter | Value |
|---|---|
| Rated current (In) | 1600 A at 40 °C |
| Sensor rating | 1600 A |
| Rated operational voltage (Ue) | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Poles | 3P |
| Rated insulation voltage (Ui) | 1000 V AC 50/60 Hz conforming to IEC 60947-2 |
| Rated impulse withstand voltage (Uimp) | 12 kV conforming to IEC 60947-2 |
| Suitable for isolation | Yes conforming to IEC 60947-2 |
| Parameter | Value |
|---|---|
| Rated ultimate breaking capacity (Icu) | 42 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 |
| Rated service breaking capacity (Ics) | 42 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| Rated short-time withstand current (Icw) | 10 kA 0.5 s conforming to IEC 60947-2 10 kA 1 s conforming to IEC 60947-2 |
| Rated short-circuit making capacity (Icm) | 88 kA 525 V AC at 50/60 Hz 88 kA 690 V AC at 50/60 Hz 105 kA 220/415 V AC at 50/60 Hz 105 kA 440 V AC at 50/60 Hz |
| Performance type | H2T |
| Parameter | Value |
|---|---|
| Breaking time, max. | 25 ms |
| Closing response time, max. | 50 ms |
| Mechanical durability (cycles) | 12500 cycles without maintenance conforming to IEC 60947-2 |
| Electrical durability (cycles) | 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-23A: 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-3: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 |
| Selectivity category | Category A |
| Parameter | Value |
|---|---|
| Control type | Push-button |
| Mounting mode | Fixed |
| Width | 276 mm |
| Height | 301 mm |
| Depth | 196 mm |
| Connection pitch | 70 mm |
| Parameter | Value |
|---|---|
| Operating ambient temperature | -25...70 °C |
| Storage ambient temperature | -40...85 °C |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Parameter | Value |
|---|---|
| Standards | IEC 60947-2 |
MPN