Skip to main content
Schneider Electric 48118 — Air Circuit Breakers

Schneider Electric 48118

MPN48118
Active

circuit breaker Masterpact NW63H1 - 6300 A - 3 poles - fixed - w/o trip unit (Planned discontinuation end of 2025, has been replaced by LV948118)

$20,180.69Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jun 2026

Specifications

48118 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact NW
RangeMasterPacT
Circuit breaker nameMasterPact NW63H1
ApplicationPower distribution protection
Control unitWithout control unit
48118 — Electrical ratings
ParameterValue
Rated current (In)6300 A at 40 °C
Sensor rating3200 A 6300 A
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
48118 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 100 kA at 525 V AC 50/60 Hz 100 kA at 690 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 100 kA at 525 V AC 50/60 Hz 100 kA at 690 V AC 50/60 Hz
Rated short-time withstand current (Icw)100 kA 1 s 100 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz 220 kA 525 V AC at 50/60 Hz 220 kA 690 V AC at 50/60 Hz
Performance typeH1 100 kA 440 V AC
48118 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.80 ms
Mechanical durability (cycles)10000 cycles with maintenance 5000 cycles without maintenance
Electrical durability (cycles)1500 cycles 440 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-2 1500 cycles 690 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-2 AC-23A: 1500 cycles 440 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3 AC-23A: 1500 cycles 690 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation1050 W
48118 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBackplate Rails
Width767 mm
Height352 mm
Depth297 mm
Connection pitch230 mm
Upside connectionRear
Downside connectionRear
48118 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to IEC 60529
Pollution degree4 conforming to IEC 60664-1
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
48118 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2
MPN
48118