Schneider Electric A9C15908 — Contactors

Schneider Electric A9C15908 Acti9 CDS Load-Shedding Contacto

MPNA9C15908
Active

Schneider Electric Acti9 CDS, single-phase load-shedding contactor, 2 channels, 1P, 230 V AC, 15 A non-priority / adjustable 5-90 A priority circuit, IP20, DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9C15908 — Identification
ParameterValue
Product / component typeLoad-shedding contactor
A9C15908 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)230 V AC - 15...10 % at 50/60 Hz
A9C15908 — Contacts & Poles
ParameterValue
Pole configuration1P
A9C15908 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
A9C15908 — Approvals
ParameterValue
StandardsEN 50081-1 NF C 61-750 EN 50081-2
A9C15908 — Mechanical
ParameterValue
Width90 mm
Height77 mm
Depth60 mm

Product details

The Schneider Electric A9C15908 is an Acti9 CDS single-phase load-shedding contactor with two channels — one non-priority circuit rated at 15 A and one priority circuit adjustable from 5 to 90 A.

The priority circuit's adjustable range (5 to 90 A) lets you set the trip threshold via the 12-position rotary dial (settings: 75, 45, 20, 90, 5, 10, 30, 60, 50, 40, 15, 25 A), so you match it to the critical load's actual draw. The 12 VA power consumption is the coil's steady-state draw — negligible for the panel's control transformer budget. The operating temperature range (-5 to 55 °C) covers most control-panel environments, and the 95 % RH at 55 °C rating confirms it handles high-humidity plant floors without condensation issues.

The 90 mm width and 77 mm height fit a standard 4-module DIN-rail footprint (10 x 9 mm pitches). The screw terminals accept up to 10 mm² flexible on the non-priority side and up to 50 mm² rigid on the priority side — sized for the higher current path.

Compliant with EN 50081-1, EN 50081-2, and NF C 61-750. Depth is 60 mm, which clears most standard enclosures.

Frequently asked questions

What are the key ratings for the A9C15908?

It is a 2-channel single-phase load-shedding contactor rated 230 V AC, 15 A on the non-priority circuit, and adjustable 5 to 90 A on the priority circuit. Power consumption is 12 VA. IP20 rated.

What are the mounting dimensions?

Width 90 mm, height 77 mm, depth 60 mm. Mounts on 35 mm DIN rail, panel, or wall. Occupies 10 x 9 mm pitches on the rail.

What compliance standards does it meet?

Compliant with EN 50081-1, EN 50081-2, and NF C 61-750. Tropicalisation class 2 per IEC 60068-1.

MPN
A9C15908