Schneider Electric A9C21442 — Contactors

Schneider Electric A9C21442 Acti9 iCT Contactor, 2P, 40 A AC

MPNA9C21442
Obsolete

Schneider Electric Acti9 iCT contactor, 2P, 40 A AC-7A / 15 A AC-7B, 127 V AC 60 Hz coil, clip-on DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9C21442 — Identification
ParameterValue
Product / component typeContactor
A9C21442 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)250 V AC 60 Hz
A9C21442 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Operating altitude2000 m
A9C21442 — Approvals
ParameterValue
StandardsIEC/EN 61095
A9C21442 — Mechanical
ParameterValue
Width36 mm
Height85 mm
Depth73.5 mm

Product details

It switches motor, heating, and lighting loads on 250 V AC 60 Hz networks, with a rated operational current of 40 A in AC-7A duty (general motor loads) and 15 A in AC-7B duty (resistive loads). The control coil is 127 V AC 60 Hz, maintained signal type — meaning the coil stays energised to hold the contacts closed.

The 15 A AC-7B rating covers resistive loads like heaters. Electrical durability is specified per duty: 100,000 cycles at 40 A AC-7A, and 30,000 cycles at 15 A AC-7B. Mechanical durability is 1,000,000 cycles, so the contactor outlasts its electrical life in most applications — the coil or contacts will wear before the mechanism does. The 2-pole configuration uses two normally-open (NO) contacts, so it switches both line and neutral (or two phases) simultaneously. Inrush power is 34 VA — relevant for sizing the control transformer if multiple contactors pull in at once.

IP20 finger-safe terminals; IP40 inside the modular enclosure. Control circuit terminals accept 1.5–2.5 mm² flexible or rigid; power circuit terminals accept up to 25 mm² rigid or 16 mm² flexible. Tightening torque: 0.8 N·m on the control side, 3.5 N·m on the power side.

Frequently asked questions

What are the key ratings of the A9C21442?

Rated operational current: 40 A AC-7A / 15 A AC-7B. Rated operational voltage: 250 V AC 60 Hz. Control coil: 127 V AC 60 Hz. Poles: 2P, 2 NO contacts. Mounting: clip-on 35 mm DIN rail. IP20 protection.

What compliance documentation is available for the A9C21442?

The contactor is certified to IEC/EN 61095 and EN/IEC 60947-4-1. Tropicalisation treatment conforms to EN 60947-4-1, EN 61095, and IEC 1095. Pollution degree 2. Operating altitude up to 2000 m.

MPN
A9C21442