Skip to main content
Schneider Electric A9C61210

Schneider Electric A9C61210 Reflex iC60N, 10 A, 2P, Curve B

MPN A9C61210
Obsolete

Schneider Electric Acti9 Reflex iC60N, integrated control MCB, 10 A, 2P, curve B, 230 V AC, 20 kA Icu at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C61210 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width81 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationControl Distribution

Product details

The Schneider Electric A9C61210 is a Reflex iC60N integrated control circuit breaker from the Acti9 range — a 10 A, 2-pole, curve B thermal-magnetic MCB with a built-in remote-control coil. It combines overcurrent protection with the ability to switch the load on and off via a pulse, a maintained signal, or a maintained very-low-voltage command, which saves panel space and wiring compared to a separate contactor and breaker.

Rated 10 A with a B curve, so it trips magnetically between 3 and 5 times In — that's 30 to 50 A — making it a good fit for resistive and light inductive loads like contactor coils, control transformers, or small lighting circuits where you want fast fault clearance without nuisance trips from inrush. Breaking capacity is 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC, per EN/IEC 60947-2. Control circuit voltage options cover 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC, so it adapts to different control schemes without a separate interface relay. The control signal can be a pulse (momentary), a maintained signal, or a maintained very-low-voltage command, giving flexibility for remote or automated switching.

This class of part — an integrated control circuit breaker — is used in control distribution panels where a single device needs to provide both overcurrent protection and remote on/off switching of a load. Typical applications include controlling contactor coils, solenoid valves, small motor starters, or lighting contactors in commercial and industrial power distribution.

MPN
A9C61210