Schneider Electric A9C61263 — Contactors

Schneider Electric A9C61263 Reflex iC60N, 63 A 2P curve B in

MPNA9C61263
Obsolete

Schneider Electric Acti9 range, Reflex iC60N integrated control circuit breaker, 63 A, 2P, curve B, thermal-magnetic trip, 20 kA breaking capacity at 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9C61263 — Identification
ParameterValue
Product / component typeIntegrated control circuit breaker
Series / rangeActi9
A9C61263 — Contacts & Poles
ParameterValue
Pole configuration2P
A9C61263 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
A9C61263 — Mechanical
ParameterValue
Width81 mm
Height84 mm
Depth77 mm

Product details

The Schneider Electric A9C61263 is a Reflex iC60N integrated control circuit breaker from the Acti9 range — a 63 A, 2-pole (2P), curve B thermal-magnetic MCB that also handles remote control functions. It's designed for distribution and control applications, combining overcurrent protection with the ability to switch loads via pulse, maintained, or toggle commands at 230 V AC control voltage. IP20 rated, so it lives inside an enclosure, not exposed to washdown.

Breaking capacity: 20 kA Icu at 230 V AC and 10 kA Icu at 400 V AC, both per EN/IEC 60947-2. Rated current 63 A, curve B. Curve B trips magnetically at 3–5× In (roughly 189–315 A), which suits resistive and lighting loads where inrush is low — not for motor starts. Thermal-magnetic trip unit handles both overload (thermal bimetal) and short-circuit (solenoid) protection in one package. Control flexibility: accepts maintained, impulse, or toggle signals at 24 V AC/DC, 48 V AC/DC, or 230 V AC. That makes it usable with PLC digital outputs, pushbuttons, or a building management system's remote trip signal. Electrical durability rated 50,000 cycles at AC-1 resistive load — solid for frequent switching in lighting or HVAC contactor-replacement roles.

Dimensions: 84 mm high, 81 mm wide, 77 mm deep. Occupies 9 mm pitches on the DIN rail — standard for a 2P MCB in the Acti9 family.

Frequently asked questions

What is the breaking capacity of A9C61263?

20 kA Icu at 230 V AC and 10 kA Icu at 400 V AC, both per EN/IEC 60947-2.

What control voltages does this breaker accept?

The control circuit accepts 24 V AC/DC, 48 V AC/DC, or 230 V AC at 50/60 Hz, with support for maintained, impulse, or toggle commands.

What is the depth of A9C61263?

77 mm.

What is the range of A9C61263?

Acti9.