Skip to main content
Schneider Electric A9C62216 — Contactors

Schneider Electric A9C62216 Reflex iC60N, 16 A, 2P, Curve C

MPNA9C62216
Obsolete

Schneider Electric Acti9 Reflex iC60N, integrated control circuit breaker, 16 A, 2P, curve C, 20 kA breaking capacity.

$406.86Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9C62216 — Identification
ParameterValue
Product / component typeIntegrated control circuit breaker
Series / rangeActi9
A9C62216 — Contacts & Poles
ParameterValue
Pole configuration2P
A9C62216 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
A9C62216 — Mechanical
ParameterValue
Width81 mm
Height84 mm
Depth77 mm

Product details

The Schneider Electric A9C62216 is a Reflex iC60N integrated control circuit breaker — a thermal-magnetic MCB with a built-in control function, so it both protects the circuit and acts as a remotely operated switch. The 2-pole version (2P) protects both phase and neutral on a single-phase 230 V AC network. Breaking capacity is 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC, per EN/IEC 60947-2. The N breaking capacity code tells you it's the standard-interrupting version in the iC60 family, not the high-performance H or L variants.

Mounts on a 35 mm symmetrical DIN rail, fixed position, occupying 9 module pitches (9 x 9 mm = 81 mm width). That's a standard footprint for a 2P MCB with integrated control, so it slots into any DIN-rail enclosure without special adapters. The white housing and IP20 finger-safe terminals are standard for panel-mounted distribution gear. Control voltage options cover both AC and DC: 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC. The control signal can be maintained (continuous command), maintained very low voltage, or impulse (pulse). That flexibility lets you wire it to a PLC digital output, a pushbutton station, or a remote SCADA contact — no separate contactor needed for the switching function. Local signalling includes a red LED for fault, green LED for device ON, and flashing patterns for device ready, tripped, or overheat. This is useful for panel troubleshooting — you can read the breaker's state at a glance without a meter.

Sourcing and lifecycle — current production, no obsolescence risk

The part belongs to the Acti9 range and the Reflex iC60N sub-family, which is a well-established platform with broad global approvals. Pollution degree 3 (industrial environment), tropicalisation class 2, and 93% relative humidity at 40 °C — all point to reliable operation in non-conditioned panel environments.

Frequently asked questions

What are the key ratings for the A9C62216?

Rated current 16 A, curve C, 2 poles. Breaking capacity is 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC per EN/IEC 60947-2. Control circuit voltage options include 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC.

What is the physical size and mounting of the A9C62216?

It mounts on a 35 mm DIN rail, fixed position, occupying 9 module pitches (81 mm width). Height is 84 mm, depth is 77 mm. The housing is white with IP20 protection.

What compliance documentation does Schneider provide for the A9C62216?

The part is certified to EN/IEC 60947-2 for breaking capacity. IP20 per IEC 60529. Pollution degree 3 per IEC 60664. The Acti9 range typically carries CE, UKCA, and EAC marks; specific UL/CSA listings should be verified against the nameplate for the exact variant.

MPN
A9C62216