Skip to main content
Schneider Electric A9C62216

Schneider Electric A9C62216 Reflex iC60N, 16 A, 2P, Curve C

MPN A9C62216
Obsolete

Schneider Electric Acti9 Reflex iC60N, integrated control circuit breaker, 16 A, 2P, curve C, 20 kA breaking capacity.

$406.86 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C62216 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width81 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationControl Distribution

Product details

The Schneider Electric A9C62216 is a Reflex iC60N integrated control circuit breaker — a thermal-magnetic MCB with a built-in control function, so it both protects the circuit and acts as a remotely operated switch. The 2-pole version (2P) protects both phase and neutral on a single-phase 230 V AC network. Breaking capacity is 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC, per EN/IEC 60947-2. The N breaking capacity code tells you it's the standard-interrupting version in the iC60 family, not the high-performance H or L variants.

Mounts on a 35 mm symmetrical DIN rail, fixed position, occupying 9 module pitches (9 x 9 mm = 81 mm width). That's a standard footprint for a 2P MCB with integrated control, so it slots into any DIN-rail enclosure without special adapters. The white housing and IP20 finger-safe terminals are standard for panel-mounted distribution gear. Control voltage options cover both AC and DC: 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC. The control signal can be maintained (continuous command), maintained very low voltage, or impulse (pulse). That flexibility lets you wire it to a PLC digital output, a pushbutton station, or a remote SCADA contact — no separate contactor needed for the switching function. Local signalling includes a red LED for fault, green LED for device ON, and flashing patterns for device ready, tripped, or overheat. This is useful for panel troubleshooting — you can read the breaker's state at a glance without a meter.

Sourcing and lifecycle — current production, no obsolescence risk

The part belongs to the Acti9 range and the Reflex iC60N sub-family, which is a well-established platform with broad global approvals. Pollution degree 3 (industrial environment), tropicalisation class 2, and 93% relative humidity at 40 °C — all point to reliable operation in non-conditioned panel environments.

MPN
A9C62216