Skip to main content
Schneider Electric A9C66316

Schneider Electric A9C66316 Reflex iC60H, 16 A, 3P, Curve D,

MPN A9C66316
Obsolete

Schneider Electric Acti9 Reflex iC60H, A9C66316, integrated control circuit breaker, 16 A, 3P, curve D, thermal-magnetic trip, 30 kA breaking capacity.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C66316 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width99 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationControl Distribution

Product details

The thermal-magnetic trip unit handles both slow thermal overloads and fast magnetic shorts. The remote control capability is the headline feature here — it accepts a maintained or impulse control signal (230 V AC, 24 V AC/DC, 48 V AC/DC) so you can open or close the breaker from a PLC output, a pushbutton, or a building management system. This makes it a fit for applications where you want to remotely shed a non-critical load or reset a circuit without sending someone to the panel. The local signaling — green LED for ON, flashing red for fault, flashing for device ready or overheat — gives you a quick visual on the panel door without needing a separate indicator.

Breaking capacity is 30 kA Icu at 220-240 V AC and 15 kA Icu at 380-415 V AC, both per EN/IEC 60947-2. That 30 kA at 240 V is the number that matters for most commercial and light industrial panels in North America on a 240/120 V split-phase or 208Y/120 V system — it means this breaker can safely interrupt a fault current up to 30,000 amps without welding its contacts or failing catastrophically. At 400 V three-phase (common in European and industrial plants), the 15 kA rating still covers a lot of service-entrance and sub-panel scenarios. The IP20 finger-safe terminals are fine for enclosed panels; if you need washdown protection, you'd put this behind a sealed door.

MPN
A9C66316