Schneider Electric A9C66316 — Contactors

Schneider Electric A9C66316 Reflex iC60H, 16 A, 3P, Curve D,

MPNA9C66316
Obsolete

Schneider Electric Acti9 Reflex iC60H, A9C66316, integrated control circuit breaker, 16 A, 3P, curve D, thermal-magnetic trip, 30 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9C66316 — Identification
ParameterValue
Product / component typeIntegrated control circuit breaker
Series / rangeActi9
A9C66316 — Contacts & Poles
ParameterValue
Pole configuration3P
A9C66316 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
A9C66316 — Mechanical
ParameterValue
Width99 mm
Height84 mm
Depth77 mm

Product details

The thermal-magnetic trip unit handles both slow thermal overloads and fast magnetic shorts. The remote control capability is the headline feature here — it accepts a maintained or impulse control signal (230 V AC, 24 V AC/DC, 48 V AC/DC) so you can open or close the breaker from a PLC output, a pushbutton, or a building management system. This makes it a fit for applications where you want to remotely shed a non-critical load or reset a circuit without sending someone to the panel. The local signaling — green LED for ON, flashing red for fault, flashing for device ready or overheat — gives you a quick visual on the panel door without needing a separate indicator.

Breaking capacity is 30 kA Icu at 220-240 V AC and 15 kA Icu at 380-415 V AC, both per EN/IEC 60947-2. That 30 kA at 240 V is the number that matters for most commercial and light industrial panels in North America on a 240/120 V split-phase or 208Y/120 V system — it means this breaker can safely interrupt a fault current up to 30,000 amps without welding its contacts or failing catastrophically. At 400 V three-phase (common in European and industrial plants), the 15 kA rating still covers a lot of service-entrance and sub-panel scenarios. The IP20 finger-safe terminals are fine for enclosed panels; if you need washdown protection, you'd put this behind a sealed door.

Frequently asked questions

What is the rated breaking capacity of the A9C66316?

It carries 30 kA Icu at 220-240 V AC and 15 kA Icu at 380-415 V AC, both per EN/IEC 60947-2.

What control voltages does the A9C66316 accept?

The control circuit accepts 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC — both maintained and impulse signals.

Does the A9C66316 require a separate earth-leakage module?

Yes, earth-leakage protection is handled by a separate block, not integrated into this device.