Skip to main content
Schneider Electric A9CR5225 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9CR5225 Acti9 REDs RCCB, 25 A, 300 mA, 2

MPNA9CR5225
Active

Schneider Electric Acti9 REDs RCCB recloser, A9CR5225, 2P, 25 A rated current, 300 mA earth-leakage sensitivity, 230 V AC, EN 50557.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9CR5225 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Local signalling / indication1 LED green/red Residual current device : ON/OFF indication Recloser : ON/OFF indication
A9CR5225 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230 V AC 50 Hz phase to neutral
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Mechanical durability (operating cycles)4000 cycles open-close
A9CR5225 — Identification
ParameterValue
Product nameActi9 REDs
Product / component typeResidual current circuit breaker (RCCB)
Device short nameREDs
A9CR5225 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Width in 9 mm modules6
Terminal connectionsGuard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
Wire stripping length12 mm
Terminal tightening torque3 N.m
Width54 mm
Height106 mm
Depth82 mm
A9CR5225 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9CR5225 — Approvals
ParameterValue
StandardsEN 50557

Product details

It is rated 25 A continuous, 300 mA earth-leakage sensitivity (Type A), 230 V AC phase-to-neutral, 2-pole, for TT and TN-S earthing systems. The recloser logic is configurable: it waits 10 s before the first reclose, allows up to 3 consecutive restarts, and stops the cycle if the insulation fault persists. If the fault is transient, the circuit is restored automatically — no manual reset needed. This is the key difference from a standard RCCB, which requires a physical reset after any trip.

Occupies 6 x 9 mm pitches (54 mm width) in the enclosure. Height 106 mm, depth 82 mm — standard for a 2P module in the Acti9 family, so it fits existing cutouts and gland-plate layouts without rework. Wire stripping length 12 mm, tightening torque 3 N·m. IP20 finger-safe protection for the front face; suitable for clean, dry indoor panel environments.

Frequently asked questions

What is A9CR5225's listed depth?

The A9CR5225 has a depth of 82 mm, width 54 mm, height 106 mm — standard 2P module dimensions for the Acti9 REDs range.

What does the fault reset earth leakage mean on A9CR5225?

The reset type is 'Fault reset earth leakage' — the device trips on earth leakage and then automatically attempts to reclose after a 10 s delay, up to 3 times, stopping if the fault persists. This is the recloser function, not a manual reset.

Where can I buy A9CR5225?

The A9CR5225 is available to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
A9CR5225