Schneider Electric A9CR5240 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9CR5240 Acti9 REDs RCCB, 40 A, 300 mA, 2

MPNA9CR5240
Active

Schneider Electric Acti9 REDs, RCCB, 2P, 40 A, 300 mA, Type A, recloser, 230 V AC, 50 Hz, DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9CR5240 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Local signalling / indication1 LED green/red Residual current device : ON/OFF indication Recloser : ON/OFF indication
A9CR5240 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)230 V AC 50 Hz phase to neutral
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Mechanical durability (operating cycles)4000 cycles open-close
A9CR5240 — Identification
ParameterValue
Product nameActi9 REDs
Product / component typeResidual current circuit breaker (RCCB)
Device short nameREDs
A9CR5240 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Width in 9 mm modules6
Terminal connectionsGuard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
Wire stripping length12 mm
Terminal tightening torque3 N.m
Width54 mm
Height106 mm
Depth82 mm
A9CR5240 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9CR5240 — Approvals
ParameterValue
StandardsEN 50557

Product details

The Schneider Electric A9CR5240 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 REDs series, rated at 40 A with a 300 mA earth leakage sensitivity (Type A). It operates on a 230 V AC, 50 Hz phase-to-neutral network and is designed for TT and TN-S earthing systems. The recloser function automatically restarts after a transient insulation fault — up to three consecutive restarts with a 180 s minimum interval between closings — and stops the cycle if a persistent fault is detected, then retries diagnosis every 2 minutes.

The 40 A rated current and 300 mA earth leakage sensitivity define the load and protection threshold — sized for outgoing circuits where nuisance tripping from leakage is a concern. The reclosing logic — 10 s reclosing time, maximum 30 operations/hour, max 3 consecutive restarts — is built for transient fault environments (e.g., outdoor lighting, irrigation) where temporary insulation breakdown clears itself. The 500 V rated insulation voltage gives headroom above the 230 V operating level. Mounts on a 35 mm symmetrical DIN rail, occupies 6 x 9 mm pitches — 54 mm wide — and needs 82 mm depth behind the panel.

Designed to EN 50557, the standard for automatic reclosing devices for RCCBs. IP20 degree of protection — suitable for dry indoor panel environments.

Frequently asked questions

Who supplies A9CR5240 and how is it quoted for volume purchases?

The A9CR5240 is supplied through independent distribution channels. For volume purchases, submit an RFQ — availability and current pricing are confirmed at quote time.

What is A9CR5240's listed depth?

The A9CR5240 has a depth of 82 mm.

What is A9CR5240's listed reset?

The reset is a fault reset earth leakage — the device resets automatically after a transient fault clears, or stops the cycle if a persistent insulation fault is detected.

What compliance documentation does this brand provide for A9CR5240?

The A9CR5240 is designed to EN 50557 and carries IP20 protection. For RoHS, REACH, UL, or IEC documentation, contact the supplier at quote time — these are typically available from the manufacturer upon request.

MPN
A9CR5240