Schneider Electric A9CR5263 — Residual Current Breakers (RCCB/RCBO)

A9CR5263 Acti9 REDs RCCB 63A 300mA Type A Recloser

MPNA9CR5263
Active

Schneider Electric Acti9 REDs RCCB recloser, 2P, 63A, 300mA Type A earth leakage, auto-reclosing, 230V AC, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9CR5263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Local signalling / indication1 LED green/red Residual current device : ON/OFF indication Recloser : ON/OFF indication
A9CR5263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)230 V AC 50 Hz phase to neutral
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Mechanical durability (operating cycles)4000 cycles open-close
A9CR5263 — Identification
ParameterValue
Product nameActi9 REDs
Product / component typeResidual current circuit breaker (RCCB)
Device short nameREDs
A9CR5263 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Width in 9 mm modules6
Terminal connectionsGuard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
Wire stripping length12 mm
Terminal tightening torque3 N.m
Width54 mm
Height106 mm
Depth82 mm
A9CR5263 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9CR5263 — Approvals
ParameterValue
StandardsEN 50557

Product details

The A9CR5263 is a Schneider Electric Acti9 REDs residual current circuit breaker (RCCB) with integrated auto-reclosing — a 2-pole recloser rated 63 A, 300 mA sensitivity, Type A earth-leakage protection, for 230 V AC 50 Hz phase-to-neutral networks (TN-S and TT earthing systems).

63 A rated current ([In]) handles the full load of a distribution outgoer — sized for a lighting or general-power submain, not a motor circuit. The 300 mA sensitivity is a fire-protection level (not personnel shock protection); it tolerates normal leakage from long cable runs or equipment filters without nuisance tripping. The auto-reclosing logic (reclose time 10 s, max 3 consecutive restarts, 180 s minimum between closings, stops on persistent insulation fault) is designed for transient earth faults — lightning, moisture, or switching surges — without sending a crew out for every trip. It monitors insulation fault presence and restarts only if the fault clears; a permanent fault locks it out.

Fixed mounting on a 35 mm symmetrical DIN rail, 2-pole width (54 mm), 106 mm tall, 82 mm deep. Occupies 6 module pitches. Neutral on the left.

Frequently asked questions

How do I get current pricing and availability for A9CR5263?

The A9CR5263 is sourced and quoted to order against an RFQ; availability and current pricing are confirmed at quote time.

What is A9CR5263's listed depth?

The A9CR5263 has a depth of 82 mm.

What is A9CR5263's listed reset?

The A9CR5263 uses a fault reset earth leakage mechanism — it resets automatically after a transient earth fault clears, and locks out on a persistent fault.

What compliance documentation does this brand provide for A9CR5263?

The A9CR5263 is designed to EN 50557 (requirements for automatic reclosing devices for RCCBs). The manufacturer provides standard compliance documentation for the Acti9 range.

MPN
A9CR5263