Skip to main content
Schneider Electric A9CR8440 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9CR8440 Acti9 REDm RCCB, 40 A, 30 mA, 4P

MPNA9CR8440
Active

Schneider Electric Acti9 REDm, 4P RCCB, 40 A, 30 mA, 50 Hz, DIN rail, grey.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9CR8440 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indication1 LED Residual current device : ON/OFF indication green
A9CR8440 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)400 V AC 50 Hz
Poles description4P
Neutral pole positionRight
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz conforming to EN 50557
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability4000 cycles 230 V AC 50 Hz open-close conforming to EN 50557
Mechanical durability (operating cycles)4000 cycles open-close
A9CR8440 — Identification
ParameterValue
Product nameActi9 REDm
Product / component typeResidual current circuit breaker (RCCB)
A9CR8440 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules14
Terminal connectionsGuard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
Wire stripping lengthPower circuit: 12 mm Signaling: 5 mm
Terminal tightening torquePower circuit: 3 N.m Signaling: 0.5 N.m
Width126 mm
Height106 mm
Depth81 mm
A9CR8440 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20 conforming to EN/IEC 60529
Pollution degree2 conforming to EN 50557
Relative humidity95 % at 55 °C
Operating altitude0...2000 m
Tropicalisation2 conforming to IEC 61008
A9CR8440 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9CR8440 is a 4-pole (4P) residual current circuit breaker (RCCB) from the Acti9 REDm series, rated at 40 A with 30 mA earth-leakage sensitivity on a 50 Hz AC network. The 30 mA sensitivity is the standard threshold for personal protection against indirect contact in TN-S and TT earthing systems — it trips before leakage current reaches a level that could cause ventricular fibrillation.

Autotest and diagnostics

This RCCB includes an automatic self-test feature that runs every 10 seconds when line voltage exceeds 195 V. If a fault is detected, the device re-checks every 2 minutes — the insulation fault diagnosis logic identifies persistent leakage and distinguishes it from a transient event. A green LED provides local ON/OFF indication for the RCCB status. Manual test is also available via the toggle control.

Pollution degree 2 per EN 50557, tropicalisation class 2 per IEC 61008. IP20 rated (finger-safe terminals), IK05 impact resistance.

Frequently asked questions

How do I get current pricing and availability for A9CR8440?

The A9CR8440 is sourced and quoted to order against an RFQ through independent distribution — availability and current pricing confirmed at quote time.

What is A9CR8440's listed depth?

The A9CR8440 has a product depth of 81 mm.

What is the reset type for A9CR8440?

The A9CR8440 uses a fault reset for earth leakage — the toggle must be manually reset after a trip caused by residual current.

What compliance documentation does the A9CR8440 carry?

The A9CR8440 is designed to EN/IEC 61008-1, with pollution degree 2 per EN 50557 and tropicalisation class 2 per IEC 61008.

MPN
A9CR8440