Schneider Electric A9D10832 — Residual Current Breakers (RCCB/RCBO)

A9D10832 Acti9 iC60H RCBO, 32 A, 10 kA, 10 mA, 1P+N

MPNA9D10832
Active

Schneider Electric Acti9 iC60H RCBO, 1P+N, 32 A rated current, 10 kA breaking capacity, 10 mA earth-leakage sensitivity, curve C, clip-on DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D10832 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D10832 — Electrical Ratings
ParameterValue
Rated current (In)32 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D10832 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D10832 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D10832 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D10832 — Approvals
ParameterValue
StandardsBS EN 61009-1 IEC 61009-1 IEC 61009-2-2 AS/NZS 61009.1

Product details

It carries a 32 A rated current (at 50 °C), a 10 kA breaking capacity (Icn at 230/240 V AC), and a 10 mA earth-leakage sensitivity. The thermal-magnetic trip unit provides both overload and short-circuit protection on a single 18 mm wide DIN-rail module.

The 10 kA breaking capacity at 230/240 V AC (Icn per IEC 61009-1) sets the maximum fault current this RCBO can safely interrupt — adequate for most commercial and light industrial final circuits where the prospective short-circuit current stays under 10 kA. The 10 mA earth-leakage threshold is a high-sensitivity trip, typically specified for circuits supplying wet areas, medical equipment, or where additional personal protection is required. The 32 A rating suits socket-outlet circuits or fixed equipment up to that load.

Clip-on mounting to a standard 45 mm grid DIN rail (EN 60715). The 18 mm width (2× 9 mm pitches) occupies a single modular slot. Neutral is on the left; the toggle provides ON/OFF local indication. IP20 finger-safe protection for panel installation.

Certified to BS EN 61009-1, IEC 61009-1, IEC 61009-2-2, and AS/NZS 61009.1 — covering RCBO performance, EMC, and Australian/New Zealand deviations. The TN earthing system is specified; tropicalisation class 2 (95 % RH at 55 °C) suits humid environments. Limitation class 3 (energy limiting) reduces let-through energy under fault conditions.

Frequently asked questions

Where can I buy A9D10832 and how do I get a price?

The A9D10832 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the breaking capacity of A9D10832?

10 kA Icn at 230/240 V AC, 50/60 Hz, per IEC 61009-1. This is the maximum fault current the RCBO can safely interrupt.

What earth-leakage sensitivity does A9D10832 have?

10 mA — a high-sensitivity trip intended for wet areas, medical circuits, or enhanced personal protection requirements.

What compliance documentation is available for A9D10832?

The RCBO is certified to BS EN 61009-1, IEC 61009-1, IEC 61009-2-2, and AS/NZS 61009.1. It is rated for TN earthing systems and tropicalisation class 2 (95 % RH at 55 °C).

MPN