A9D15820 Acti9 iC60H RCBO, 20 A C-curve, 10 kA, 100 mA

MPNA9D15820
Obsolete

Schneider Electric Acti9 iC60H RCBO, 1P+N, 20 A, C-curve, 10 kA Icn at 240 V AC, 100 mA earth-leakage sensitivity, clip-on DIN rail mount, A9D15820.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D15820 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D15820 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D15820 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D15820 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D15820 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D15820 — Approvals
ParameterValue
StandardsIEC 61009-2-2 IEC 61009-1

Product details

It combines a 20 A thermal-magnetic MCB (C-curve) with integrated 100 mA earth-leakage protection, all in a 1P+N format. Clip-on DIN rail mounting and 2 x 9 mm pitch width make it a direct swap into any Acti9 or standard distribution board.

The 20 A rated current at 50 °C is the continuous load it carries without tripping — sized for lighting, socket circuits, or small appliance groups. The 100 mA earth-leakage sensitivity is a common choice for general-purpose socket circuits where 30 mA would be too sensitive for leakage from connected equipment. Integrated earth-leakage saves a separate RCD module and one DIN space — the whole RCBO fits in 18 mm.

This is an outgoer device — it protects a final subcircuit, not an incoming main. The 1P+N format switches the phase and breaks the neutral, with neutral on the left. Wire stripping length is 14 mm top, 13 mm bottom. Padlockable with a 4 mm padlock for lockout/tagout.

Frequently asked questions

What is the breaking capacity of A9D15820?

10,000 A Icn at 240 V AC, 50/60 Hz. That's the maximum fault current it can safely interrupt under standard test conditions per IEC 61009-1.

What earth-leakage sensitivity does A9D15820 have?

100 mA. This is integrated into the RCBO — no separate RCD module needed.

Where can I buy A9D15820 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers on this page.

MPN
A9D15820