Schneider Electric A9D37210 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D37210 Acti9 iC60 RCBO, 10 A, 30 mA, B

MPNA9D37210
Active

Schneider Electric Acti9 iC60 RCBO, A9D37210, 2P, 10 A rated, 30 mA earth leakage, B curve, 10 kA Icn, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D37210 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D37210 — Electrical Ratings
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D37210 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D37210 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D37210 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D37210 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

Part identity and deployment context

The Schneider Electric A9D37210 is an Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection, in a 2-pole (2P) configuration rated at 10 A with 30 mA earth-leakage sensitivity, B-curve trip characteristic, and a 10 kA Icn breaking capacity at 230 V AC. The integrated earth-leakage protection covers both protected poles, making it a single-device solution for outgoing circuits requiring both overcurrent and residual-current protection.

The 10 A rated current (In) with B-curve magnetic tripping (3–5 × In, i.e. 30–50 A instantaneous) suits resistive and light inductive loads where inrush is modest — lighting circuits, small motor starters, or general socket outlets in residential or light commercial distribution. The 30 mA earth-leakage sensitivity provides personal protection against direct contact, meeting the standard requirement for socket-outlet circuits in most IEC-based installations. Breaking capacity is rated at 10 kA Icn per EN/IEC 61009-2-1 at 230 V AC, with a higher 15 kA Icu per EN/IEC 60947-2 — the Icn figure governs coordination with upstream devices in a typical domestic or commercial panel; the Icu rating gives headroom for industrial distribution where fault levels may be higher.

Tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible (with or without ferrule); wire-strip length is 12 mm for top or bottom connection. The toggle provides local signalling for ON, OFF, and fault-trip positions.

MPN
A9D37210