Skip to main content
Schneider Electric A9D37210

Schneider Electric A9D37210 Acti9 iC60 RCBO, 10 A, 30 mA, B

MPN A9D37210
Active

Schneider Electric Acti9 iC60 RCBO, A9D37210, 2P, 10 A rated, 30 mA earth leakage, B curve, 10 kA Icn, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D37210 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite

All specifications

A9D37210 additional specifications
ParameterValue
Depth78 mm
Width36 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

Part identity and deployment context

The Schneider Electric A9D37210 is an Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection, in a 2-pole (2P) configuration rated at 10 A with 30 mA earth-leakage sensitivity, B-curve trip characteristic, and a 10 kA Icn breaking capacity at 230 V AC. The integrated earth-leakage protection covers both protected poles, making it a single-device solution for outgoing circuits requiring both overcurrent and residual-current protection.

The 10 A rated current (In) with B-curve magnetic tripping (3–5 × In, i.e. 30–50 A instantaneous) suits resistive and light inductive loads where inrush is modest — lighting circuits, small motor starters, or general socket outlets in residential or light commercial distribution. The 30 mA earth-leakage sensitivity provides personal protection against direct contact, meeting the standard requirement for socket-outlet circuits in most IEC-based installations. Breaking capacity is rated at 10 kA Icn per EN/IEC 61009-2-1 at 230 V AC, with a higher 15 kA Icu per EN/IEC 60947-2 — the Icn figure governs coordination with upstream devices in a typical domestic or commercial panel; the Icu rating gives headroom for industrial distribution where fault levels may be higher.

Tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible (with or without ferrule); wire-strip length is 12 mm for top or bottom connection. The toggle provides local signalling for ON, OFF, and fault-trip positions.

MPN
A9D37210