Schneider Electric A9D37216 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D37216 Acti9 iC60 RCBO, 16 A, 30 mA, B

MPNA9D37216
Active

Schneider Electric Acti9 iC60 RCBO, A9D37216, 2P, 16 A, 30 mA, B curve, 10 kA Icn, DIN rail clip-on.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D37216 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D37216 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D37216 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D37216 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D37216 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D37216 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

B curve and 30 mA trip — what they mean on the line

The A9D37216: The B curve (magnetic tripping limit 3–5 x In) means the unit trips instantaneously between 48 A and 80 A. That suits circuits with resistive or lightly inductive loads — lighting, small heaters, control transformers — where inrush is modest. The 30 mA residual sensitivity is the standard for personnel protection (shock hazard) per IEC 60364. On a distribution outgoer, this RCBO protects both the cable and the person touching the load side.

Panel integration

Clip-on DIN rail mounting, 36 mm wide (4 x 9 mm pitches), 78 mm deep. IP40 in a distribution enclosure, IP20 bare. The toggle provides local ON/OFF and fault-trip indication.

Frequently asked questions

Where can I buy A9D37216?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9D37216?

10 kA Icn at 220–240 V AC per EN/IEC 61009-2-1, and 15 kA Icu per EN/IEC 60947-2.

What standards does A9D37216 comply with?

EN/IEC 60947-2 and EN/IEC 61009-2-1. Quality labels include NF, IMQ, VDE, KEMA-KEUR.