Schneider Electric A9D40610 Acti9 RCBO, 10 A, 30 mA, 6 kA

MPN A9D40610
Active

Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 10 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D40610 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230/240 V AC 50 Hz
IP ratingIP20
Temp storage max70 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-25 °C
Storage temperature-25...70 °C
ColorWhite
Depth70 mm
Width18 mm
Height93 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...55 °C

Product details

It protects a single phase against overload, short-circuit, and earth leakage from a single DIN-rail footprint. Rated 10 A at 30 °C with a 6 kA breaking capacity (Icn at 230/240 V AC, 50 Hz), it is sized for final subcircuits in residential and commercial distribution boards where both overcurrent and earth-leakage protection are required on the same outgoing way.

The 30 mA earth-leakage sensitivity provides additional protection against indirect contact and fire risk from earth faults — standard for socket-outlet circuits and wet-area final subcircuits in most IEC-based installations. The C-curve magnetic trip (5–10 × In) suits loads with moderate inrush, such as lighting banks, small appliances, and general-purpose socket circuits. The 6 kA breaking capacity is the standard domestic/commercial rating under IEC 61009-1; it is adequate for most final subcircuits fed by a transformer or a main switchboard with a prospective fault current below 6 kA. For higher fault levels, a current-limiting upstream MCB or fuse would be needed. Integrated earth-leakage protection means this RCBO replaces two separate devices (MCB + RCCB) in one 18 mm wide module, saving two DIN-rail pitches per way. The thermal-magnetic trip unit provides the overcurrent protection; the residual current coil handles the earth-leakage function.

The 18 mm width occupies two 9 mm pitches, matching the Acti9 modular system for clean row alignment. IP20 finger-safe terminals suit installation inside a locked or tool-accessible enclosure. The tunnel-type terminals accept up to 16 mm² rigid upstream and 10 mm² downstream, covering standard 1.5–6 mm² final subcircuit wiring. Strip length is 13 mm upstream, 11 mm downstream.