Schneider Electric A9D40632 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D40632 Acti9 ISPN Vigi RCBO, 32 A, 10 m

MPNA9D40632
Active

Schneider Electric Acti9 ISPN Vigi, RCBO, 1P+N, 32 A, C-curve, 10 mA earth leakage, 6 kA Icn, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D40632 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D40632 — Electrical Ratings
ParameterValue
Rated current (In)32 A at 30 °C
Rated operational voltage (Ue)230/240 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D40632 — Identification
ParameterValue
Product nameISPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
A9D40632 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminal (upstream) 1...16 mm² rigid Tunnel type terminal (downstream) 1...10 mm² rigid Tunnel type terminal (upstream) 1...16 mm² flexible Tunnel type terminal (downstream) 1...10 mm² flexible
Wire stripping length11 mm for downstream connection 13 mm for upstream connection
Terminal tightening torque2 N.m upstream 2 N.m downstream
Width18 mm
Height93 mm
Depth70 mm
A9D40632 — Environmental
ParameterValue
Operating ambient temperature-25...55 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D40632 — Approvals
ParameterValue
StandardsAS/NZS 61009.1 IEC 61009-2-2

Product details

Rated 32 A at 30 °C with a C-curve magnetic trip (5...10 x In), it breaks 6000 A Icn at 230/240 V AC 50 Hz. The 10 mA sensitivity is the key spec here: that's the level used for personal shock protection in wet or exposed circuits (bathrooms, construction-site sockets, medical locations), not just equipment protection.

Clip-on mounting to a standard DIN rail, 2 x 9 mm pitches wide (18 mm). Depth is 70 mm, height 93 mm. That 18 mm width is the critical dimension for a crowded enclosure — it occupies exactly one standard modular position, so you can plan the rail fill without surprises. Wire stripping length is 13 mm upstream, 11 mm downstream. Tightening torque 2 N.m both sides.

Certified to AS/NZS 61009.1 and IEC 61009-2-2, the dual standard for RCBOs covering both overcurrent and residual-current protection in a single device. Suitability for isolation is marked, and the toggle provides ON/OFF indication with locking facilities.

Frequently asked questions

What is the closest alternative to A9D40632 in the Acti9 range?

Within the Acti9 ISPN Vigi family, the closest sibling is the same physical footprint and breaking capacity but with a different rated current or earth-leakage sensitivity. The A9D40632 is the 32 A / 10 mA variant; a 30 mA version (same current) or a 16 A / 10 mA version would be the natural alternatives if the protection thresholds don't match your circuit. Check the spec line yourself — the only deltas are the In and IΔn values; form, fit, and function are identical.