Schneider Electric A9D47213 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D47213 Acti9 iC60 RCBO, 13 A, 30 mA, Ty

MPNA9D47213
Active

Schneider Electric Acti9 iC60 RCBO, A9D47213, 2P, 13 A rated, 30 mA earth leakage, Type B curve, 10 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D47213 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D47213 — Electrical Ratings
ParameterValue
Rated current (In)13 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D47213 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D47213 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D47213 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D47213 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The Schneider Electric A9D47213 is an Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection, rated 13 A with 30 mA earth-leakage sensitivity and a Type B tripping curve. The integrated 30 mA residual-current element covers personnel protection against direct-contact faults.

Breaking capacity and standards compliance

Rated breaking capacity Icn is 10 kA at 220...240 V AC, 50 Hz per EN/IEC 61009-2-1; the ultimate breaking capacity Icu reaches 15 kA per EN/IEC 60947-2. Quality marks include VDE, KEMA-KEUR, NF, and IMQ — accepted across European and some Asian markets. Overvoltage category III per IEC 60364 confirms it is rated for fixed-installation use downstream of the utility meter.

The 9 mm pole pitch matches standard busbar systems for Acti9 enclosures. IP40 in a distribution enclosure, IP20 for the terminal area — suitable for dry indoor panels. The white housing carries local signalling for ON, OFF, and fault-trip states.

Frequently asked questions

How do I get current pricing and availability for A9D47213?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels.

What is the breaking capacity of A9D47213?

Icn is 10 kA at 220...240 V AC per EN/IEC 61009-2-1; Icu is 15 kA per EN/IEC 60947-2.

What compliance documentation does this brand provide for A9D47213?

The part carries VDE, KEMA-KEUR, NF, and IMQ quality labels. It complies with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards.

MPN
A9D47213