Schneider Electric A9D50220 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D50220 Acti9 iC60 RCBO, 20 A, 2P, 10 kA

MPNA9D50220
Active

Schneider Electric Acti9 iC60 RCBO, A9D50220, 2P, 20 A, C-curve, 10 kA Icn, 300 mA earth-leakage, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D50220 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D50220 — Electrical Ratings
ParameterValue
Rated current (In)20 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D50220 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D50220 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D50220 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D50220 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The Schneider Electric A9D50220 is an Acti9 iC60 RCBO — a combined overcurrent and residual-current device in a 2-pole, 20 A, C-curve configuration. It integrates thermal-magnetic overcurrent protection (C-curve, magnetic trip 5–10 x In) with 300 mA earth-leakage detection in one 36 mm wide DIN-rail module, saving a slot over separate MCB+RCCB. Rated 20 A at 50 Hz AC, it carries a 10 kA Icn breaking capacity per EN/IEC 61009-2-1 and a 15 kA Icu per EN/IEC 60947-2 at 220–240 V. The 300 mA residual sensitivity is set for equipment protection rather than personnel shock — typical for distribution outgoers feeding fixed machinery, lighting, or socket circuits where nuisance tripping from leakage on long cable runs needs to be avoided.

Clip-on DIN rail mounting, 4 x 9 mm pole pitches (36 mm wide). Tunnel terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable; strip 12 mm and torque to 2 N·m. The 9 mm connection pitch between poles matches standard busbar comb sets for the Acti9 range. IP40 in a distribution enclosure, IP20 bare. Local signalling shows ON, OFF, and fault trip status via the toggle position — no need to meter the load side to confirm a trip.

Frequently asked questions

What standards does the A9D50220 comply with?

It complies with EN/IEC 60947-2 and EN/IEC 61009-2-1, and carries VDE, NF, and IMQ quality labels. Overvoltage category III per IEC 60364.