Skip to main content
Schneider Electric A9D51225 — Residual Current Breakers (RCCB/RCBO)

A9D51225 Acti9 iC60 RCBO 25A C-curve 300mA 10kA

MPNA9D51225
Obsolete

Schneider Electric Acti9 iC60 RCBO, A9D51225, 2P, 25 A, C-curve, 300 mA earth leakage, 10 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D51225 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D51225 — Electrical Ratings
ParameterValue
Rated current (In)25 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D51225 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H2 RCBO
A9D51225 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width36 mm
Height110 mm
Depth75.5 mm
A9D51225 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D51225 — Approvals
ParameterValue
StandardsAS/NZS 61009.1 IEC 61009-2-2 IEC 61009-1

Product details

The Schneider Electric A9D51225 is an Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection in a 2-pole, 25 A, C-curve variant. It integrates earth-leakage detection at 300 mA sensitivity and thermal-magnetic overcurrent protection into one 36 mm wide DIN-rail module, saving a panel position versus separate devices.

Rated 25 A at 50 °C with a C-curve trip characteristic — magnetic release between 5 and 10× In, so it handles motor inrush and lighting ballast surges without nuisance tripping, but still clears a hard short fast. The 10 kA Icn breaking capacity at 240 V AC is the maximum fault current the device can safely interrupt; for most commercial and light industrial distribution boards on a 240 V single-phase supply this is adequate, but verify the prospective short-circuit current at the point of installation. The 300 mA earth-leakage threshold is a protection level for fire prevention or equipment protection, not personnel shock protection (that would be 30 mA or lower). Tightening torque is 3.5 N·m top, 2 N·m bottom.

Frequently asked questions

What are the key ratings for the A9D51225?

The A9D51225 is a 2-pole RCBO rated 25 A with a C-curve, 300 mA earth-leakage sensitivity, and 10 kA breaking capacity at 240 V AC. It clips onto a DIN rail and occupies 36 mm (4 x 9 mm pitches).

Where can I buy the A9D51225?

The A9D51225 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote.

What standards does the A9D51225 comply with?

The A9D51225 complies with IEC 61009-1, IEC 61009-2-2, and AS/NZS 61009.1, covering RCBO performance and safety requirements for residual current and overcurrent protection.

MPN