Schneider Electric A9D52416 Acti9 iC60 RCBO, 4P C-curve 16 A

MPN A9D52416
Active

Schneider Electric Acti9 iC60 RCBO, 4-pole, 16 A rated current, C-curve, 300 mA earth-leakage sensitivity, 6 kA breaking capacity, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D52416 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage380...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite

All specifications

A9D52416 additional specifications
ParameterValue
Depth78 mm
Width72 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The 6 kA breaking capacity at 380–415 V AC (Icu per EN/IEC 60947-2) and 6000 A Icn per EN/IEC 61009-2-1 cover most commercial and light-industrial outgoing feeders. The thermal-magnetic trip unit handles both overload and short-circuit; the integrated earth-leakage module adds personnel and equipment protection against ground faults.

The 16 A rating and C-curve mean this RCBO is sized for general-purpose loads with moderate inrush — lighting banks, small motor circuits, socket outlets. The 300 mA earth-leakage threshold is a standard for protection against fire risk from ground faults, not personnel shock (that requires 30 mA or lower). Breaking capacity of 6 kA at 400 V class is adequate for most distribution boards downstream of a larger upstream breaker; limitation class 1 means it lets through a defined let-through energy consistent with standard coordination rules. The clip-on DIN-rail mount (9 mm pole pitch, 8 pitches wide = 72 mm) snaps directly into a standard 35 mm rail inside an IP40 distribution enclosure.

Integration notes

Tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible conductors; wire stripping length is 12 mm for top or bottom connection. The toggle provides local indication of ON, OFF, and fault-trip states. Overvoltage category III per IEC 60364 suits fixed-installation distribution boards. The IP40 rating applies inside the distribution enclosure; the device itself is IP20.