Skip to main content
Schneider Electric A9D50232 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D50232 Acti9 iC60 RCBO, 32 A C-curve, 3

MPNA9D50232
Active

Schneider Electric Acti9 iC60 RCBO, A9D50232, 2P, 32 A rated, C-curve, 300 mA earth-leakage sensitivity, 10 kA Icn breaking capacity, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D50232 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D50232 — Electrical Ratings
ParameterValue
Rated current (In)32 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D50232 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D50232 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D50232 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D50232 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The A9D50232 is a 2-pole RCBO (residual-current circuit breaker with overcurrent protection) from the Acti9 iC60 family, rated 32 A with a C-curve trip characteristic — meaning the magnetic release operates between 5 and 10 times the rated current (160–320 A), per the datasheet. The integrated earth-leakage protection trips at 300 mA sensitivity, which is the standard threshold for protection against fire risk from ground faults in fixed wiring — not personnel protection (that calls for 30 mA). The breaking capacity is 10 kA Icn per EN/IEC 61009-2-1 at 220–240 V AC, 50 Hz, with an ultimate breaking capacity (Icu) of 15 kA per EN/IEC 60947-2. The limitation class is 3 per EN/IEC 61009-2-1, which limits let-through energy under short-circuit conditions — relevant when coordinating with downstream equipment. The thermal-magnetic trip unit gives a time-delayed response on overloads and instantaneous magnetic trip on shorts. Per the datasheet, the electrical durability is 5000 cycles and mechanical durability 20,000 cycles, so this is a distribution-grade device, not a switching-duty contactor.

Clip-on mounting to DIN rail per EN/IEC 60715. The 2-pole device occupies 4 modules of 9 mm pitch (36 mm total width), so it fits a standard 18-module distribution board with room for adjacent devices. Tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible conductors; wire stripping length is 12 mm for top or bottom connection.

Frequently asked questions

What is the breaking capacity of A9D50232?

The rated short-circuit breaking capacity (Icn) is 10,000 A at 220–240 V AC 50 Hz per EN/IEC 61009-2-1, and the ultimate breaking capacity (Icu) is 15 kA at the same voltage per EN/IEC 60947-2.

What earth-leakage sensitivity does A9D50232 have?

The integrated earth-leakage protection trips at 300 mA sensitivity. This is the standard threshold for fire protection in fixed wiring, not personnel protection.

Where can I buy A9D50232 and how is it quoted?

The part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
A9D50232