Skip to main content
Schneider Electric A9D51810 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D51810 iC60H RCBO, 10A D-curve, 30mA, 1

MPNA9D51810
Active

Schneider Electric Acti9 iC60H RCBO, A9D51810, 1P+N, 10 A rated, D-curve, 30 mA earth leakage, 10 kA breaking capacity, DIN rail clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D51810 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D51810 — Electrical Ratings
ParameterValue
Rated current (In)10 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D51810 — Identification
ParameterValue
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D51810 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D51810 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D51810 — Approvals
ParameterValue
StandardsBS EN 61009-1 IEC 61009-1 IEC 61009-2-2 AS/NZS 61009.1

Product details

The Schneider Electric A9D51810 is an Acti9 iC60H residual current breaker with overcurrent protection (RCBO) — a single-module (18 mm wide, 2 x 9 mm pitches) device combining thermal-magnetic overcurrent protection and 30 mA earth-leakage detection in one DIN-rail unit. Breaking capacity is 10,000 A Icn at 230/240 V AC, 50/60 Hz, which covers most commercial and light industrial outgoing circuits where the prospective fault current stays under that threshold. The D-curve (10–20× In magnetic trip) suits loads with high starting currents — small motors, pumps, compressors — that would trip a B or C curve on startup.

Clip-on mounting to DIN rail (EN 60715), 18 mm width per module. The 77.5 mm depth and 110 mm height fit standard distribution boards; the 45 mm grid distance aligns with busbar systems. Tightening torque: 3.5 N·m top, 2 N·m bottom. Wire strip lengths are 14 mm top, 13 mm bottom. IP20 finger-safe terminals suit enclosed panel use. The unit is padlockable (Ø 4 mm padlock) for lockout/tagout during maintenance. ON/OFF toggle provides local visual indication of contact position.

Listed to BS EN 61009-1, IEC 61009-1, IEC 61009-2-2, and AS/NZS 61009.1 — the core RCBO standards for overcurrent and residual current protection. Suitable for TN earthing systems. Lifecycle status is current production; this is a standard catalogue item, not a phase-out or NRND line. Electrical durability rated at 5,000 cycles, mechanical at 20,000 cycles — typical for a panel-protection device, not a daily-switching contactor.

Frequently asked questions

What is the breaking capacity of the A9D51810?

The A9D51810 has a breaking capacity Icn of 10,000 A at 230/240 V AC, 50/60 Hz, per IEC 61009-1.

Where can I buy the A9D51810 RCBO?

The A9D51810 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What does the D-curve on the A9D51810 mean?

The D-curve (magnetic trip at 10–20× In) allows the 10 A RCBO to pass high inrush currents — up to 250 A surge — without tripping, making it suitable for motor, transformer, or lighting loads with a high starting surge.

MPN
A9D51810