Skip to main content
Schneider Electric A9D52613 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D52613 Acti9 iDPN Vigi RCBO, 13 A C-cur

MPNA9D52613
Obsolete

Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 13 A, C-curve, 100 mA earth leakage, 6 kA breaking capacity, DIN rail clip-on.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D52613 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D52613 — Electrical Ratings
ParameterValue
Rated current (In)13 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D52613 — Identification
ParameterValue
Product nameActi9 iDPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiDPN N Vigi
A9D52613 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9D52613 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9D52613 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9D52613 is an Acti9 iDPN Vigi residual-current circuit breaker with overcurrent protection (RCBO) — one module wide, combining a 13 A thermal-magnetic MCB and a 100 mA earth-leakage trip in a single 1P+N package.

Rated 13 A at 230...240 V AC, 50 Hz, with a breaking capacity of 6000 A Icn per EN/IEC 61009-2-1. The 100 mA earth-leakage sensitivity (AC type, integrated) protects against insulation faults and indirect contact, not direct human touch (that would need 30 mA). It is sized for distribution outgoers feeding fixed equipment, socket circuits, or sub-distribution where a 30 mA RCD would nuisance-trip on leakage from permanently connected loads. Thermal-magnetic trip technology means the thermal bimetal handles overloads (slow response, inverse-time) and the solenoid handles short-circuits (instantaneous above the C-curve threshold).

Connection pitch is 9 mm between phase and neutral, matching the standard Acti9 comb-busbar pitch.

Frequently asked questions

What is the breaking capacity of A9D52613?

6000 A Icn at 230...240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1.

Where can I buy A9D52613 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance standards does A9D52613 meet?

It is designed and tested to EN/IEC 61009-2-1 (RCBO standard), with tropicalisation class 2 per IEC 60068-1, pollution degree 3, and overvoltage category III per IEC 60364.

MPN
A9D52613