Schneider Electric A9D54210 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D54210 Acti9 iC60 RCBO, 10 A, 2P, 300 m

MPNA9D54210
Active

Schneider Electric Acti9 iC60 RCBO, 2P, 10 A, C curve, 300 mA earth-leakage, 10 kA Icn, DIN-rail clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D54210 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D54210 — Electrical Ratings
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D54210 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D54210 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D54210 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D54210 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The Schneider Electric A9D54210 is an Acti9 iC60 RCBO — a combined 2-pole residual-current circuit breaker with overcurrent protection, rated 10 A with a C curve and 300 mA earth-leakage sensitivity.

Breaking capacity is 10 kA Icn at 230 V per EN/IEC 61009-2-1, with an ultimate breaking capacity Icu of 15 kA per EN/IEC 60947-2. That Icu figure tells you the device can safely interrupt a fault once at the higher level — useful for coordination studies where the upstream device clears faster. The C curve trips magnetically between 5 and 10 times In, so for a 10 A RCBO that means instantaneous trip between 50 A and 100 A, typical for general-purpose distribution with moderate inrush (lighting, small motor starters). Earth-leakage protection is integrated at 300 mA sensitivity, covering both poles. The 300 mA threshold is common for protection against fire risk in circuits supplying fixed equipment, not for personal shock protection (which would require 30 mA). Thermal-magnetic trip unit gives you the standard bimetal overload protection plus a solenoid for short-circuits.

Strip length 12 mm for top or bottom connection; tightening torque 2 N·m.

Frequently asked questions

What is the breaking capacity of A9D54210?

10 kA Icn at 230 V AC per EN/IEC 61009-2-1, and 15 kA Icu per EN/IEC 60947-2.

What earth-leakage sensitivity does A9D54210 have?

300 mA, integrated for both protected poles.

Where can I buy A9D54210?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What compliance documentation does A9D54210 carry?

Certified to EN/IEC 60947-2 and EN/IEC 61009-2-1, with quality labels NF, IMQ, KEMA-KEUR, and VDE.

MPN
A9D54210