Skip to main content
Schneider Electric A9D54220 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D54220 Acti9 iC60 RCBO, 20 A C-curve 2P

MPNA9D54220
Active

Schneider Electric Acti9 iC60 RCBO, A9D54220, 2P, 20 A rated, C-curve, 300 mA earth leakage, breaking capacity 10 kA Icn at 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D54220 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D54220 — Electrical Ratings
ParameterValue
Rated current (In)20 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D54220 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D54220 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D54220 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D54220 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The Schneider Electric A9D54220 is an Acti9 iC60 RCBO — a 2-pole residual-current circuit breaker with overcurrent protection, rated 20 A with a C-curve magnetic trip (5 to 10 x In) and 300 mA earth-leakage sensitivity. Breaking capacity is 10 kA Icn per EN/IEC 61009-2-1 at 220–240 V AC, 50 Hz, with an ultimate Icu of 15 kA per EN/IEC 60947-2. The trip unit is thermal-magnetic: the thermal bimetal handles overloads, the magnetic coil handles short-circuits. The C-curve holds up to 5 x In (100 A) for instantaneous trips, so it tolerates motor inrush and capacitive loads without nuisance tripping, but clears fast on hard faults.

IP40 in a distribution enclosure, IP20 bare — suitable for indoor panel use, not for wet or outdoor locations without an outer cabinet.

Approvals include IMQ, NF, VDE, and KEMA-KEUR — covering Italian, French, German, and Dutch certification bodies. The part is tropicalised (class 2) for 95% RH at 55 °C. Local signalling shows ON, OFF, and fault-trip status on the toggle.

Frequently asked questions

What is the breaking capacity of A9D54220?

10 kA Icn at 220–240 V AC per EN/IEC 61009-2-1, and 15 kA Icu per EN/IEC 60947-2. The Icn rating governs its RCBO duty; Icu is the ultimate withstand under the industrial standard.

Where can I buy A9D54220 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What does the C-curve mean on this RCBO?

The C-curve magnetic trip operates between 5 and 10 times the rated current (100–200 A for this 20 A unit). It's the standard choice for general-purpose distribution circuits feeding socket outlets, small motors, and lighting — it tolerates moderate inrush without nuisance trips.

MPN
A9D54220