Schneider Electric A9D54232

Schneider Electric A9D54232 Acti9 iC60 RCBO, 32 A, 30 mA, C-

MPN A9D54232
Active

Schneider Electric Acti9 iC60 RCBO, 2P, 32 A, C-curve, 300 mA earth leakage, 10 kA Icn, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D54232 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite
Depth78 mm
Width36 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9D54232 is an Acti9 iC60 RCBO — a combined miniature circuit breaker and residual-current device in a single 36 mm wide, 2-pole module that clips onto DIN rail.

Rated 32 A (In) with a breaking capacity of 10 kA Icn at 220–240 V AC per EN/IEC 61009-2-1, and 15 kA Icu per EN/IEC 60947-2. The 10 kA Icn is the service breaking capacity — the current level the device can interrupt repeatedly under standard conditions — while the 15 kA Icu is the ultimate (one-shot) capacity. The 300 mA earth-leakage sensitivity suits circuits where a 30 mA device would cause nuisance tripping — typically fixed equipment without hand-held loads, such as distribution sub-mains, lighting circuits, or industrial socket outlets where the protective conductor path is monitored but not personnel-protection critical. If your application requires direct touch protection, a 30 mA RCBO variant is the correct choice.

Tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible conductors; wire-strip length is 12 mm for top or bottom connection. The toggle provides local signalling for ON, OFF, and fault-trip positions. IP40 in a distribution enclosure, IP20 at the terminals.

Carries quality labels KEMA-KEUR, IMQ, VDE, and NF, covering acceptance in key European markets. Overvoltage category III per IEC 60364, suitable for fixed-installation distribution boards. Tropicalisation class 2 for humid environments up to 95 % RH at 55 °C.