Schneider Electric A9D55706 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D55706 Acti9 DPN Vigi RCBO, 6 A, 30 mA,

MPNA9D55706
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, A9D55706, 3P+N, 6 A rated, 30 mA earth leakage, B curve, 6 kA breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D55706 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D55706 — Electrical Ratings
ParameterValue
Rated current (In)6 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description3P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D55706 — Identification
ParameterValue
Product nameActi9 DPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameDPN N Vigi
A9D55706 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules10
Terminal connectionsTunnel type terminal top or bottom 0.75...16 mm² rigid Tunnel type terminal top or bottom 0.33...10 mm² flexible Tunnel type terminal top or bottom 0.33...10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width90 mm
Height91 mm
Depth78.5 mm
A9D55706 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-30...70 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity90 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9D55706 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

It protects a three-phase outgoing circuit against overload, short-circuit (thermal-magnetic trip, B curve, 3–5× In magnetic threshold), and earth leakage at 30 mA sensitivity.

The 6 A rated current (In) is the continuous load the device carries without tripping — size the upstream conductor and load to stay under this. The 30 mA earth-leakage threshold provides personnel protection per IEC 60364 — it trips on any ground fault above that level. The 3P+N poles description means it switches all three phases and the neutral, with the neutral on the left side of the module.

The module occupies 10 x 9 mm pitches — 90 mm width total, with 18 mm between phases and 9 mm between phase and neutral. The tunnel-type terminals accept 0.75–16 mm² rigid or 0.33–10 mm² flexible wire; strip 15 mm and torque to 2 N·m. IP20 on the device body, IP40 inside a modular enclosure — keep the panel door closed during operation.

Frequently asked questions

Where can I buy the A9D55706?

The A9D55706 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the A9D55706 used for?

It is a combined RCBO (residual-current circuit breaker with overcurrent protection) for three-phase outgoing circuits, providing overload, short-circuit, and 30 mA earth-leakage protection in a single DIN-rail module.

What is the breaking capacity of the A9D55706?

The breaking capacity is 6000 A Icn at 380...415 V AC 50/60 Hz, conforming to EN/IEC 61009-2-1.

What standards does the A9D55706 comply with?

It complies with EN/IEC 61009-2-1 for RCBOs, and carries pollution degree 3 and overvoltage category III per IEC 60364. Tropicalisation class 2 per IEC 60068-1 is also listed.

MPN
A9D55706