Specifications

A9D60616 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D60616 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D60616 — Identification
ParameterValue
Product nameActi9 iDPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiDPN N Vigi
A9D60616 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9D60616 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9D60616 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

It combines a thermal-magnetic overcurrent trip (curve B, 3...5 x In magnetic threshold) and integrated earth-leakage protection in a single 1P+N module, saving a DIN-rail position compared to a separate MCB and RCCB. Breaking capacity is 6000 A Icn at 230...240 V AC, 50 Hz, per EN/IEC 61009-2-1 — sufficient for most residential and light commercial distribution boards where the prospective short-circuit current stays under that threshold. The limitation class 3 rating means it limits let-through energy well, aiding downstream coordination.

Installation and mounting

Clip-on mounting to DIN rail, occupying 4 pitches at 9 mm per pole (36 mm total width). Neutral is on the left, phase on the right — check busbar orientation before committing the assembly. Terminals accept 1...16 mm² rigid or 1...10 mm² flexible (with or without ferrule); tightening torque is 2 N.m, strip length 15 mm. IP20 on the device body, IP40 inside a modular enclosure per IEC 60529.

Environmental and durability

Electrical and mechanical durability each rated at 20,000 cycles, which aligns with typical panel life in non-frequent-switching distribution roles.

Frequently asked questions

What is the breaking capacity of A9D60616?

6,000 A Icn at 230...240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1.

What is the earth-leakage sensitivity of this RCBO?

30 mA sensitivity, integrated into the combined overcurrent and residual-current device.

Where can I buy A9D60616?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN