Skip to main content
Schneider Electric A9D61820 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D61820 Acti9 iC60 RCBO, 20 A, 30 mA, C-

MPNA9D61820
Active

Schneider Electric Acti9 iC60N RCBO, 1P+N, 20 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D61820 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D61820 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D61820 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N RCBO
A9D61820 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D61820 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D61820 — Approvals
ParameterValue
StandardsAS/NZS 61009.1 IEC 61009-2-2 IEC 61009-1

Product details

The Schneider Electric A9D61820 is an Acti9 iC60N RCBO — a combined residual current breaker with overcurrent protection in a single 18 mm wide DIN-rail module. It protects a single pole plus neutral (1P+N) outgoer circuit, rated 20 A at 50 °C with a C-curve trip characteristic and integrated 30 mA earth-leakage protection. The 6 kA breaking capacity at 230/240 V AC (Icn) covers most residential and light commercial panelboards in TN earthing systems.

Clip-on mounting to DIN rail, 18 mm width (2 x 9 mm pitches). The 77.5 mm depth fits standard 45 mm grid enclosures. Tightening torque is 3.5 N·m top, 2 N·m bottom. IP20 finger-safe — intended for enclosed panel use, not washdown or outdoor exposure. Padlockable with a 4 mm shackle for LOTO lockout.

Current-production part (lifecycle stage: current). No end-of-life notice or successor announced. Compliance documentation covers AS/NZS 61009.1, IEC 61009-2-2, and IEC 61009-1 — the RCBO standards for Australia/NZ and international markets.

Frequently asked questions

What compliance standards does A9D61820 meet?

It is certified to AS/NZS 61009.1, IEC 61009-2-2, and IEC 61009-1 — covering RCBO requirements for overcurrent and earth-leakage protection.

MPN
A9D61820