Skip to main content
Schneider Electric A9D64806 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D64806 Acti9 iC60 RCBO, 6 A C-Curve, 30

MPNA9D64806
Obsolete

Schneider Electric Acti9 iC60 RCBO, A9D64806, 1P+N, 6 A rated at 50 °C, C-curve, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 240 V AC, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D64806 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D64806 — Electrical Ratings
ParameterValue
Rated current (In)6 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D64806 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N RCBO
A9D64806 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D64806 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D64806 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2

Product details

It protects a 1P+N final subcircuit against both overload/short-circuit (thermal-magnetic trip, C-curve) and earth leakage (30 mA sensitivity). The 6 A rating at 50 °C means it is sized for lighting or small appliance circuits drawing up to 6 A continuous, not motor or heater loads. The 30 mA earth-leakage threshold provides personnel protection per IEC 61009-1. The neutral is on the left, and the device is padlockable (Ø 4 mm hasp) for lockout/tagout isolation — it is marked suitable for isolation per the standard.

The 77.5 mm depth fits standard distribution board enclosures with a 45 mm grid distance. The toggle actuator protrudes minimally; allow clearance above and below for the stripping lengths (13 mm bottom, 14 mm top) when landing conductors. The IP20 rating means it is intended for installation inside a closed panel or enclosure, not exposed to washdown or outdoor moisture.

Frequently asked questions

What is A9D64806's listed depth?

The A9D64806 has a depth of 77.5 mm, which fits standard distribution board enclosures with a 45 mm grid distance.

What is the A9D64806 used for?

The A9D64806 is a 1P+N RCBO (residual current breaker with overcurrent protection) rated 6 A, C-curve, 30 mA earth leakage. It protects a single-phase final subcircuit against overload, short-circuit, and earth faults in a distribution board.

Where can I buy the A9D64806 and how is it quoted?

The A9D64806 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Schneider provide for A9D64806?

The A9D64806 is certified to IEC 61009-1 and IEC 61009-2-2. It carries a suitability-for-isolation marking and is padlockable for lockout/tagout. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration of compliance with your RFQ.

MPN