Schneider Electric A9D67316 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D67316 Acti9 iC60 RCBO, 3P C-curve 16 A

MPNA9D67316
Active

Schneider Electric Acti9 iC60 RCBO, 3P, C-curve, 16 A, 30 mA earth leakage, 6 kA breaking capacity, DIN rail clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D67316 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D67316 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)380...415 V AC 50 Hz
Poles description3P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D67316 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D67316 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width54 mm
Height86 mm
Depth78 mm
A9D67316 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D67316 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The Schneider Electric A9D67316 is a 3-pole Acti9 iC60 RCBO — a combined overcurrent and residual-current device rated for 16 A (C-curve) with 30 mA earth-leakage sensitivity. It clips onto DIN rail, occupies 6 x 9 mm pitches (54 mm wide), and is intended as an outgoer in distribution boards.

Mounts via clip-on onto standard DIN rail. The tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable; strip length is 12 mm for top or bottom connection. The unit is IP40 inside a distribution enclosure (IP20 for the terminal area). Local signalling shows ON, OFF, and fault-trip status via the toggle position.

Breaking capacity is 6 kA Icn / Icu at 380–415 V AC, 50 Hz, per EN/IEC 61009-2-1 and EN/IEC 60947-2. Limitation class 1 per the same standard. Overvoltage category III per IEC 60364. Quality marks include NF, KEMA-KEUR, IMQ, and VDE. The thermal-magnetic trip unit is rated for 10,000 electrical cycles and 20,000 mechanical cycles.

Frequently asked questions

Where can I buy the A9D67316?

The A9D67316 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of the A9D67316?

The breaking capacity is 6 kA Icn / Icu at 380–415 V AC, 50 Hz, certified to EN/IEC 61009-2-1 and EN/IEC 60947-2.

What is the earth-leakage sensitivity of the A9D67316?

The earth-leakage sensitivity is 30 mA, integrated into the RCBO unit.